In two SEEG patients, greedy selection reached 90% of all-contact single-pulse site information with 3-4 contacts
A brain-computer interface that writes to the brain through SEEG stimulation must verify which site it stimulated. This analysis measured how identification of a stimulated site from one 6 mA pulse changed with the number of readout contacts. Using archived OpenNeuro ds004457 features for two patients, it compared random contact subsets with greedy forward selection performed on training trials only. A Euclidean nearest-centroid decoder used 28 ten-millisecond bins from 15 to 295 ms after the pulse. For sub-1 (39 sites, 20 contacts), all contacts gave a mean 0.97 bits per pulse; greedy selection reached 90% of this value with 4 contacts, while random subsets needed 12. For sub-3 (43 sites, 6 contacts), all contacts gave 1.26 bits; greedy selection reached 90% with 3 contacts, while random subsets needed 5. One greedy contact gave 0.38 and 0.77 bits for sub-1 and sub-3, respectively, compared with 0.22 and 0.44 bits for a random single contact. Greedy subsets gave more bits than the random mean in every split for k=2-8 in sub-1 and k=1-4 in sub-3. The first selected contact varied between splits. These findings are limited to two patients, one run, offline analysis, sparse readout montages, few trials, and overlapping half splits. Stimulation of each site in one block may let slow drift add site information and raise accuracy; the split bands are not independent confidence intervals. The results do not show that adding contacts reduces performance.
SEEG · electrical stimulation · brain-computer interface · site identification · readout contacts · nearest centroid · Wolpaw bits · greedy forward selection · OpenNeuro ds004457
References
3- usesNear SEEG Stimulation Sites Were Less Separable in Two Patients, but Distance Predicted Accuracy in Only One sci:sha256:d21e251915d9ad828755c69c22a0195effcf731f198e039f1d802bff5bc836cf
The analysis uses the binned single-trial features and provenance files of this package without change.
- usesIn two SEEG patients, 10–13 response-selected sites carried about 2 bits per pulse, more than all sites in 50/50 offline test splits sci:sha256:f4bb30cfa481e83b305d103a3b95a046f9224e8815a8879f1545fe4ee6d76e3d
That package measured bits per pulse against the number of stimulation sites. This package measures bits per pulse against the number of readout contacts on the same data.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
The analysis documents OpenNeuro ds004457 v1.0.2 as the raw source for sub-1 and sub-3. The imported feature arrays and provenance files are preserved in this package.
Cited by
1 publicationPublic catalog entries on Sciscape.
- supportsOne repeated SEEG site retained identification accuracy across 50 minutes, while cross-site timing effects remained anatomically confounded
This work gives the block-drift limit as open. For the one clean repeated site, a template from another block 50 min away gave the same identification accuracy as a same-block template.