Site templates increased 20–100 ms shaft log scores over shaft means in five SEEG sessions

We tested electrode shaft readers in five public SEEG sessions from OpenNeuro ds004457 version 1.0.2. A shaft label was the shared letter prefix of an adjacent stimulation pair. The site reader kept one waveform template per site and added site probabilities within each shaft. The comparison reader used one mean waveform per shaft. Both fitted means on the first three pulses per site and a probability scale on the fourth pulse. The final four pulses per site gave 732 test pulses across 183 sites. At 20–100 ms, the site reader increased the shaft log score in all five sessions. The patient mean score increased from 0.785 to 1.204 bits per pulse. The mean increase was 0.419 bits, with a descriptive patient bootstrap interval of 0.305–0.557 bits. The exact two-sided sign-flip reference was 0.0625. Mean accuracy increased from 50.08% to 60.23%. The score benefit remained with a shared covariance and at 30–100 ms. Before-pulse scores were near zero. The result applies to the fixed retrospective site pulse split. Tests of a live brain interface remain necessary. The package includes code, compact voltage data, fitted models, all test probabilities, and four figures. A hash-pinned raw rebuild matched all 30 input arrays and five event tables. A clean replay reproduced the results and figures exactly.

stereoelectroencephalography · SEEG · electrical stimulation · shaft classification · waveform templates · probability calibration

Admitted 1 citing publication

References

5
  1. usesA joint SEEG shape decoder did not show a clear mean gain over one selected pair in four patient sessions sci:sha256:81f77d4f52365d5b14fed7d3d6db7b430a2cf478b9a6a6062540c4e90bbd8e7c

    This work supplied the MIT-licensed source retrieval, MEF extraction, and data reading code inherited through the input publication. The license and credit are preserved.

  2. usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886

    This work supplied the recording-pair and site eligibility rules, the within-window voltage features, and the fixed covariance rule. We retained these rules for the shaft readers.

  3. usesEight selected sites raised accuracy in all five SEEG sessions but raised log score in four sci:sha256:6ea14d902f7540805304f1e86e0d9539a65d008e19a638b20889ef52c0a3d361

    This work supplied the exact 5 ms voltage inputs, event tables, source metadata, raw file manifest, and extraction code. Their hashes were checked before the new shaft analysis.

  4. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The analyzed public SEEG dataset was OpenNeuro ds004457 version 1.0.2; the exact raw subset was checked against saved SHA-256 hashes.

  5. doi:10.1523/JNEUROSCI.1325-22.2023

Cited by

1 publication