A fixed SEEG reader showed excess contact overlap in wrong site calls at 20 to 100 ms in five patients
We tested whether wrong stimulation site calls stayed near the true site in public SEEG data. We used OpenNeuro ds004457 version 1.0.2: five patients, 138 sites, and 15 fixed bipolar recording pairs. Four early pulses per site fitted a fixed covariance reader. Four later pulses tested it. At 20 to 100 ms, mean site accuracy was 33.71% and shaft accuracy was 60.39%. Among wrong calls, the share on the true shaft exceeded a uniform wrong-site reference by 22.99 percentage points after the pulse and 3.60 points before it. The paired increase was 19.40 points, with positive values in all five patients. A descriptive patient bootstrap interval was 8.37 to 30.06 points; the exact two-sided sign-flip reference was 0.0625. Shared stimulation contacts supplied 97.1% of this observed group increase. Separate pairs on the same shaft added only 0.56 points. The result supports a spatial error audit for stimulation feedback readers. It does not establish neural cause or live interface performance. The split was retrospective, site order was blocked, and these sessions had prior use. The package preserves every call, all fitted models, three figures, source code, data, and provenance. A fresh raw rebuild matched all 2,453,000 voltage bins and all event fields. A separate numerical replay matched all results exactly.
stereoelectroencephalography · SEEG · electrical stimulation · brain-computer interface · signal classification · spatial error analysis
References
7- usesA joint SEEG shape decoder did not show a clear mean gain over one selected pair in four patient sessions sci:sha256:81f77d4f52365d5b14fed7d3d6db7b430a2cf478b9a6a6062540c4e90bbd8e7c
This work supplied inherited MIT-licensed source retrieval and MEF extraction code. Code credit and its license are preserved.
- usesAt ranks set by 80% pre-pulse fit energy, pre-pulse PCA retained less repeated site voltage than response PCA in five SEEG sessions at 20–500 ms sci:sha256:2cd29c089f1d0466b782df1321baedf3de9e9cf870ccf7dc5daa86273e8d6ef6
This work supplied inherited metadata selection and source signal extraction methods. Code credit and its license are preserved.
- usesPulse time and earlier fit labels gave 98.6 percent site accuracy in 97 offline SEEG tasks from eight patients sci:sha256:d90ef48cdd8313b45bb4215d9e3f0242b5f5c94140aaa514c4a029b3c7907717
This prior clock-label audit informed the before-pulse control and the limits on claims from blocked site recordings.
- usesSite templates increased 20–100 ms shaft log scores over shaft means in five SEEG sessions sci:sha256:51bf7064c784f04a75adfd8a89df15e2ff459310fe920738f7a48577d505d227
This prior study motivated the distinction between site and shaft labels. Our spatial error audit uses a different remote-shaft candidate set and does not repeat its reader comparison.
- usesThe mean response minus pre-pulse SEEG order score was 0.001 at 15 fixed readouts in five sessions at 20 to 500 ms sci:sha256:f60b36fd022d37deb79c1c1406b661b1449e5eeb54c0780291ce666caeb0308c
This publication supplied the exact compact SEEG data, source metadata, remote-shaft cohort, pulse order, and hash-pinned raw rebuild code. The new study tests spatial error structure.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
Source data: OpenNeuro ds004457 version 1.0.2; saved metadata identifies this exact release as CC0.
- doi:10.1523/JNEUROSCI.1325-22.2023