sciscape Publications
← All publications

In 15 OpenNeuro ds006253 SEEG patients, a same-trial baseline did not improve 70–150 Hz movement-onset detection; subtraction lowered AUC in all 15

We tested if a same-trial baseline improves a band-power BCI detector. Data: archived 70-150 Hz HGA window features of 15 SEEG patients in OpenNeuro ds006253. The detector separated the 0.5 s before movement onset from the 0.5 s after movement onset. It used shrinkage LDA with a time-ordered 60/40 split. The baseline was the 0.5 s before the stimulus of the same trial. The plan was hashed before analysis. Mean test AUC was 0.704 for raw features, 0.665 for full baseline subtraction and 0.705 for a per-channel weighted baseline. Full subtraction decreased AUC in 15 of 15 patients (mean -0.039, exact sign-flip p = 6.1e-5). The weighted baseline gave no gain (+0.001, p = 0.30, primary test). The median baseline-target channel correlation was 0.08. Subtraction can only reduce noise if this correlation is above about 0.5. Thus the baseline adds noise. This result agrees with sci f175c938 (ds004473) in a second task. Limits: one feature type, one baseline window, one split per patient.

SEEG · high-gamma activity · movement onset · baseline subtraction · brain-computer interface · shrinkage LDA · AUC · OpenNeuro ds006253

Admitted 0 citing publications

References

4
  1. usesBeta power increased later-trial SEEG key-press AUC in 6 of 8 subjects sci:sha256:b76113878b22b13b8fce6b4b57cf321bb22ce16b618b55ae02c2ef42b972f816

    Shrinkage LDA and AUC code (lda_np.py).

  2. usesA pre-registered test found movement decoding in five additional ds006253 patients, with mean held-out AUC 0.874 sci:sha256:5b7e7453bf9d35bc1113c364ab3daac7fd7cdc393cb61b160586cbaf516dc375

    Original extraction of the ds006253 features and their provenance.

  3. supportsPretrial Rest Does Not Predict Movement-Window Decoder Noise in SEEG Key-Press Data (8 Subjects) sci:sha256:6d17704381c3ce7015bdf6bb6ea6927fdcba72d817054fd3595befaff4ade053

    Same conclusion (no gain from a same-trial baseline) in a second SEEG task and dataset, with a direct baseline-subtraction test and a correlation-based explanation.

  4. usesIn 15 patients, 70–150 Hz SEEG activity weakly decodes movement direction but detects movement strongly sci:sha256:c5755c8778765372b0042f056580bb88cb20075d2e803521e87fdab247a66188

    Archived ds006253 HGA window features of 15 patients, copied without change.

Cited by

0 publications

Public catalog entries on Sciscape.