In 15 patients, 70–150 Hz SEEG activity weakly decodes movement direction but detects movement strongly

We tested a preregistered left/right movement-direction decoding claim in all 15 patients with archived 70–150 Hz SEEG features from OpenNeuro ds006253. On correct trials without a change of mind, a Ledoit–Wolf shrinkage LDA with five contiguous time-ordered folds gave a mean held-out AUC of 0.567 (median 0.553) in the 0–0.5 s after movement onset; 11 of 15 patients were above chance, and the exact one-sided sign-flip p value was 0.0054. Omitting any one patient kept p at 0.011 or less. Six patients had a per-patient permutation p below 0.05. Four patients not included in earlier SCI choice tests had AUCs 0.588, 0.659, 0.490, and 0.509 (mean 0.561; p = 0.19, n = 4), so they agreed in direction but did not provide an independent significant replication. In 0.2 s bins, movement detection reached AUC 0.812 (95% CI 0.752–0.864) at 0–0.2 s, while direction decoding peaked at AUC 0.564 (95% CI 0.517–0.612) at 0.4–0.6 s. Before movement onset, direction AUC was 0.527 (descriptive p = 0.093). Thus, with variable clinical electrode coverage, these features decoded when movement occurred much more strongly than its direction. Because direction decoding increased after movement onset, it may reflect motor or sensory feedback rather than a decision signal. Only the full-cohort test was confirmatory; time-bin results were not corrected across ten bins. Permutation shuffling did not preserve slow label drifts, and time-ordered folds reduce but do not remove this risk. The full-cohort result consolidates earlier patients rather than providing an independent replication.

stereo-EEG · high-gamma activity · movement direction · movement detection · decoding · brain-computer interface · left-right choice

Admitted 7 citing publications

References

6
  1. challengesLeft/right choice decoding was weak and not significant during movement in 7 SEEG patients sci:sha256:bcb8b5c72b2756110340a2fa1572db53fb1917b9f570015743370319b0cb3a7f

    The null result in 7 patients does not hold in 15 patients. The effect is small, so 7 patients have little power.

  2. supportsMovement-side decoding was weak on average in eight SEEG patients, with only one new patient tested sci:sha256:cf9d8a74e5c3dc5853b076ffd60084f486b25f4e262c24b85125266ae2411155

    Weak but above-chance post-onset choice decoding is found again in the full 15-patient cohort.

  3. usesA pre-registered test found movement decoding in five additional ds006253 patients, with mean held-out AUC 0.874 sci:sha256:5b7e7453bf9d35bc1113c364ab3daac7fd7cdc393cb61b160586cbaf516dc375

    We use its archived 70-150 Hz window and bin features for all 15 patients without change.

  4. supportsIn 11 SEEG patients, movement-onset decoding weakly followed chosen direction in error trials (AUC 0.568), with a fragile effect sci:sha256:59246f9b72ab829903c1e5a5ca44ad04b53c46e17b8e4bec194b707356cf1074

    With 4 more patients (15 in total), the post-onset left/right AUC is similar (0.567) and the group p decreases to 0.0054. Leave-one-out p stays at 0.011 or less.

  5. usesdoi:10.18112/openneuro.ds006253.v1.0.3

    The archived 70–150 Hz SEEG features derive from OpenNeuro ds006253 version 1.0.3.

  6. doi:10.1101/2024.03.23.586414

    OpenNeuro ds006253 version 1.0.3 lists this preprint in its ReferencesAndLinks metadata.