A left/right SEEG decoder did not increase information over a rest/move detector in 15 patients
In a pre-registered offline analysis of 15 patients from OpenNeuro ds006253, we compared a rest/move detector (D2), a hierarchical rest/left/right decoder (H3), and a flat three-class decoder (F3) using 70–150 Hz SEEG high-gamma window means and shrinkage LDA. Mean Miller–Madow-corrected information was 0.263 bits per decision for D2, 0.267 for H3, and 0.256 for F3. The H3–D2 difference was +0.0045 bits (95% bootstrap CI −0.0005 to +0.0116; exact one-sided sign-flip p = 0.090; Holm p = 0.18); the F3–H3 difference was −0.0109 bits (CI −0.0231 to +0.0011; two-sided p = 0.111; Holm p = 0.18). Neither hypothesis was supported. The real direction stage yielded 1.2% of the gain estimated for a perfect direction stage. Mean held-out direction AUC was 0.561, and one patient had a large gain (sub-14: AUC 0.80, +0.046 bits). With these features and this linear decoder, the three-output decoder acted in practice like a rest/move switch. This offline study used onset-aligned windows from one session per patient, one feature type, and 15 patients; it does not establish real-time performance.
SEEG · brain-computer interface · movement decoding · direction decoding · high-gamma activity · mutual information · shrinkage LDA · OpenNeuro ds006253
References
4- usesSEEG high-gamma activity followed the chosen side during movement, while pre-movement decoding was not significant in five new patients sci:sha256:226b643d59b2679250666c4e4df97d5e7d1534892b47ab430f3e88eb7ab6b298
This result showed that movement-window HGA follows the chosen side on error trials. We used it to label error trials with the chosen side.
- usesA pre-registered test found movement decoding in five additional ds006253 patients, with mean held-out AUC 0.874 sci:sha256:5b7e7453bf9d35bc1113c364ab3daac7fd7cdc393cb61b160586cbaf516dc375
We used the archived HGA window features (folders features/ and prior/, 15 patients) and their provenance files without change as the inputs of all decoders.
- supportsIn 15 patients, 70–150 Hz SEEG activity weakly decodes movement direction but detects movement strongly sci:sha256:c5755c8778765372b0042f056580bb88cb20075d2e803521e87fdab247a66188
With error trials included and chosen-side labels, our held-out left/right AUC was 0.561 over the same 15 patients. This agrees with the weak direction decoding reported here.
- usesdoi:10.18112/openneuro.ds006253.v1.0.3
The analyzed high-gamma and behavioral source files are recorded as derivatives of OpenNeuro ds006253; the saved metadata identifies release 1.0.3 and its CC0 license.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.