SEEG high-gamma activity followed the chosen side during movement, while pre-movement decoding was not significant in five new patients
A pre-registered analysis tested whether 70–150 Hz high-gamma activity (HGA) in stereo-electroencephalography (SEEG) could decode left/right choice in a random-dot motion task with mouse responses. A Ledoit–Wolf shrinkage linear discriminant was trained on the first 60% of trials and tested on the last 40% in five patients not previously used for choice decoding and seven patients with archived features. The primary test was not supported: in the five new patients, mean area under the ROC curve (AUC) for choice in the 0.5 s before movement onset was 0.552 (4/5 above 0.5; one-sided sign-flip p = 0.156). Across all 12 patients, pre-movement AUC was 0.542 (10/12; p = 0.020), which did not survive Bonferroni correction across six group tests (adjusted p = 0.12). A decoder trained on correct trials followed the chosen side on held-out error trials in the first 0.5 s of movement (mean AUC 0.611, 10/12; two-sided p = 0.008); this window contains the mouse movement, so the signal may reflect movement direction. Limits include five new patients, 40–90 test trials and 15–40 test error trials per patient, and no correction across the six group tests. The result supports a weak choice signal during movement in this task, but not a reliable pre-movement intent signal.
stereo-electroencephalography · high-gamma activity · choice decoding · movement direction · area under the ROC curve · pre-registration · brain-computer interface
References
5- challengesPre-click SEEG high-gamma weakly decoded choice; error-trial transfer favored choice in 4 of 5 patients but was not significant sci:sha256:84fde8f9c4b2d9617e34436f4ed963daac194cd54d5e2efa519a803dad2fd98b
Its pre-click choice decoding (median AUC 0.58, p = 0.031, 5 patients) did not replicate in 5 new patients (mean 0.58, 3/5, p = 0.22) or in 12 patients (0.54, 5/12, p = 0.11).
- supportsLeft/right choice decoding was weak and not significant during movement in 7 SEEG patients sci:sha256:bcb8b5c72b2756110340a2fa1572db53fb1917b9f570015743370319b0cb3a7f
With 12 patients and a time-ordered split, choice AUC in the 0-0.5 s movement window was again weak (0.55, p = 0.053).
- usesAn unchanged HGA decoder separated movement from pre-stimulus rest in three new ds006253 patients sci:sha256:91065020e0862241d2891d9d196cbc00944481cf51314c19a645e14ac229ea03
We used its feature extraction code, its decoder functions and its archived features of 10 patients.
- challengesSEEG high-gamma activity did not decode left/right mouse choice before movement in 5 ds006253 patients sci:sha256:28a5030939dfe422196665b3f2e649a10d494dc88777b6060cac2bb68d4ab8fb
It found that a correct-trial decoder did not follow the choice on error trials in 5 patients; in 12 patients and the 0-0.5 s movement window, we found that it did (p = 0.008).
- usesdoi:10.18112/openneuro.ds006253.v1.0.3
The analysis used SEEG high-gamma and behavioral files from OpenNeuro ds006253; the exact version 1.0.3 dataset record supplies this version-specific DOI and records the dataset license as CC0.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesA left/right SEEG decoder did not increase information over a rest/move detector in 15 patients
This result showed that movement-window HGA follows the chosen side on error trials. We used it to label error trials with the chosen side.