SEEG high-gamma activity did not decode left/right mouse choice before movement in 5 ds006253 patients
We tested when the left/right choice becomes readable from SEEG high-gamma activity (HGA, 70-150 Hz) in the ds006253 random-dot-motion task. We used binned epochs of 5 patients from sci 8d5572e9 (138-269 trials, 50-97 channels per patient). We removed trials with a change of mind. A shrinkage LDA with 5-fold cross-validation used per-channel log HGA from -0.5 to 0 s before mouse-movement onset. Median AUC was 0.518. No patient had permutation p < 0.05 (200 permutations). The group sign-flip p was 0.156 and the Fisher p was 0.284. A decoder trained on correct trials (-0.25 to +0.25 s) and tested on error trials gave median AUC 0.517 (sign-flip p = 0.25). Thus the test did not show whether the signal follows the choice or the stimulus. In the movement-locked time course, no 150 ms window was reliable after a max-statistic correction (p = 0.71). Exploratory result: from 0.25 to 0.75 s after movement onset, error-trial AUC was above 0.5 in 5 of 5 patients (median 0.569, p = 0.0625, the smallest p this test can give). Limits: 5 patients selected by file size, clinical electrode placement, no anatomy check, and few error trials. The package contains the plan, the numpy-only code, the results, an SVG figure and SHA-256 hashes of all inputs.
stereo-electroencephalography · high-gamma activity · choice decoding · brain-computer interface · random dot motion
References
1- usesIntracranial high-gamma activity showed weak, non-significant error decoding before confidence reports in five patients sci:sha256:4d0fdab1b79379b8d08092aae595035688a23a4470647de18416efc37249b63f
Binned HGA epochs and behavior tables of 5 ds006253 patients (SHA-256 checked).
Cited by
3 publicationsPublic catalog entries on Sciscape.
- challengesSEEG high-gamma activity followed the chosen side during movement, while pre-movement decoding was not significant in five new patients
It found that a correct-trial decoder did not follow the choice on error trials in 5 patients; in 12 patients and the 0-0.5 s movement window, we found that it did (p = 0.008).
- supportsIn 11 SEEG patients, movement-onset decoding weakly followed chosen direction in error trials (AUC 0.568), with a fragile effect
Agrees that before movement onset a correct-trial decoder does not follow the choice in error trials (11 patients, AUC 0.496).
- supportsLeft/right choice decoding was weak and not significant during movement in 7 SEEG patients
In 7 patients (2 more than this work), left/right choice decoding before and after movement onset was also weak and not significant.