In 11 SEEG patients, movement-onset decoding weakly followed chosen direction in error trials (AUC 0.568), with a fragile effect

A direction decoder for a brain-computer interface should represent the chosen direction. Correct trials do not distinguish choice from stimulus direction, so this offline analysis trained a shrinkage linear discriminant on correct trials and evaluated held-out error trials, where choice and stimulus were opposite. We analyzed archived 70–150 Hz high-gamma features from 11 patients in OpenNeuro ds006253 (2,483 trials, including 660 errors; change-of-mind trials and trials with NaN features were excluded). In the prespecified 0–0.5 s after movement onset window, mean error-trial choice AUC was 0.568 (8/11 patients above 0.5; exact one-sided sign-flip p = 0.033), equal to the correct-trial AUC (0.568). Before movement onset, error-trial AUC was 0.496; in the 0–0.5 s after-stimulus window it was 0.510. The result indicates weak direction information about executed choice after movement onset, with no detected stimulus-direction information. The effect was fragile: leave-one-patient-out p values ranged from 0.011 to 0.066; without sub-14, mean error-trial AUC was 0.538 (p = 0.066). This was an offline analysis of one dataset and one author-provided feature type; error trials had lower coherence and longer reaction times, electrode locations were not used, and error trials may include motor slips. The exact OpenNeuro release of the source files is not established by the archived file records.

SEEG · brain-computer interface · error trials · choice decoding · high-gamma activity · shrinkage LDA · movement onset · OpenNeuro ds006253

Admitted 1 citing publication

References

5
  1. usesMovement detection reached AUC 0.953 in one new ds006253 SEEG patient, and post-stimulus scores exceeded rest in 10 of 11 patients sci:sha256:a5aa774cfefca331d229bb2f890136231db5500a866a8f362a70324fb04b3faa

    Uses the archived 70-150 Hz window features of the 11 ds006253 patients from this package.

  2. supportsLeft/right choice decoding was weak and not significant during movement in 7 SEEG patients sci:sha256:bcb8b5c72b2756110340a2fa1572db53fb1917b9f570015743370319b0cb3a7f

    A pre-registered primary test in 11 patients supports its uncorrected secondary result that error-trial movement-window decoding follows the choice (AUC 0.568, p = 0.033).

  3. supportsSEEG high-gamma activity did not decode left/right mouse choice before movement in 5 ds006253 patients sci:sha256:28a5030939dfe422196665b3f2e649a10d494dc88777b6060cac2bb68d4ab8fb

    Agrees that before movement onset a correct-trial decoder does not follow the choice in error trials (11 patients, AUC 0.496).

  4. supportsPost-movement SEEG high-gamma activity decoded choice in three new patients, but pre-movement decoding was not confirmed sci:sha256:e7b1011676b9967acb4938016375413fe4156af9a634bc14f044eeb98d9f8782

    Movement-window left/right decoding is above chance in 11 patients (correct trials AUC 0.568, 8/11, p = 0.018), but weaker than 0.61 in 3 patients.

  5. doi:10.1101/2024.03.23.586414

Cited by