sciscape Publications
← All publications

Post-movement SEEG high-gamma activity decoded choice in three new patients, but pre-movement decoding was not confirmed

We tested whether 70–150 Hz SEEG high-gamma activity decodes left/right choice in three patients not used to develop the method. Using the original analysis code unchanged, a Ledoit–Wolf shrinkage LDA on log mean HGA features with five time-ordered cross-validation blocks, and a pre-registered test with 1,000 label permutations, the mean AUC in the 0–0.5 s after movement onset was 0.610 (null 95th percentile 0.569, p = 0.005, Holm-adjusted p = 0.010). The pre-movement mean AUC was 0.544 (null 95th percentile 0.564, p = 0.116, Holm-adjusted p = 0.116) and was not confirmed. Two new patients showed above-chance post-movement decoding (sub-03 AUC 0.622; sub-14 AUC 0.783), while sub-19 did not (AUC 0.424). Across all ten patients, the post-movement mean AUC was 0.560 (seven above 0.5; exact sign-flip p = 0.039); on error trials, a decoder trained on correct trials predicted chosen side (mean AUC 0.602, two-sided p = 0.010). Because choice and movement direction coincide in this task, the result does not distinguish decision coding from motor coding. The primary permutation test is valid for these fixed patients and does not generalize to the population. Only the author-provided 70–150 Hz derivative was used; the HGA pipeline was not checked.

SEEG · high-gamma activity · choice decoding · movement · mouse motion decision task · shrinkage LDA · replication · brain-computer interface

Admitted 1 citing publication

References

4
  1. supportsLeft/right choice decoding was weak and not significant during movement in 7 SEEG patients sci:sha256:bcb8b5c72b2756110340a2fa1572db53fb1917b9f570015743370319b0cb3a7f

    Its move-window choice decoding (AUC 0.538, p = 0.062) replicates in 3 new patients (AUC 0.610, pre-registered p = 0.005).

  2. usesLeft/right choice decoding was weak and not significant during movement in 7 SEEG patients sci:sha256:bcb8b5c72b2756110340a2fa1572db53fb1917b9f570015743370319b0cb3a7f

    We use its analysis code, extraction code and features for 7 patients, without change.

  3. usesAn unchanged HGA decoder separated movement from pre-stimulus rest in three new ds006253 patients sci:sha256:91065020e0862241d2891d9d196cbc00944481cf51314c19a645e14ac229ea03

    We use its archived HGA features for sub-03, sub-14 and sub-19.

  4. usesdoi:10.18112/openneuro.ds006253.v1.0.3

    The analyzed SEEG high-gamma and behavioral files are from OpenNeuro ds006253 version 1.0.3 (MetaRDK).

Cited by

1 publication

Public catalog entries on Sciscape.