Time-bin features did not improve left/right movement decoding in 15 SEEG patients
In a preregistered offline analysis of 15 patients with stereoelectroencephalography (SEEG), we tested whether five 0.2 s bins of 70–150 Hz activity from 0–1.0 s after movement onset improved left/right direction decoding over one 0–0.5 s window mean. With correct trials, Ledoit–Wolf shrinkage linear discriminant analysis, and five contiguous time-ordered folds, the mean AUC difference was −0.002 (95% bootstrap CI −0.033 to +0.030); five-bin features were better in 6/15 patients (one-sided exact sign-flip p = 0.54). We found no evidence of improvement. Against a single 0–1.0 s mean, the five-bin features were slightly worse (mean difference −0.019, 95% CI −0.037 to −0.001; 3/15 better; one-sided p = 0.97, Holm p = 0.97; descriptive direction only). The five-bin features were above chance (mean AUC 0.571, 12/15 patients; p = 0.0024, Holm p = 0.0048), but direction decoding remained weak across feature sets (mean AUC 0.57–0.59). The exploratory 0–1.0 s mean comparison with the 0–0.5 s mean was +0.017 (9/15 better, p = 0.058). For this linear decoder and trial count, a single window mean is a reasonable starting feature. This offline study used one session per patient and windows aligned to known movement onset; it does not rule out gains from nonlinear decoders, more trials, a lower-dimensional time basis, or other frequency bands.
stereoelectroencephalography · brain-computer interface · movement direction · high gamma activity · linear discriminant analysis · time course · decoding
References
2- usesA pre-registered test found movement decoding in five additional ds006253 patients, with mean held-out AUC 0.874 sci:sha256:5b7e7453bf9d35bc1113c364ab3daac7fd7cdc393cb61b160586cbaf516dc375
Input features (70-150 Hz HGA window and 0.2 s bin means, 15 ds006253 patients) are copied without change from this package.
- supportsIn 15 patients, 70–150 Hz SEEG activity weakly decodes movement direction but detects movement strongly sci:sha256:c5755c8778765372b0042f056580bb88cb20075d2e803521e87fdab247a66188
Our reference arm (0-0.5 s window, mean AUC 0.573) agrees with the weak direction decoding reported there (0.567). Multi-bin features did not change this conclusion.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesOn ds006253 SEEG features in 15 patients, fixed nonlinear decoders did not improve direction decoding; RBF added 0.011 AUC for movement detection
We used the archived ds006253 per-trial 70-150 Hz window features from this package without change.
- usesIn 15 SEEG patients, a movement detector responded after stimulus onset; post-stimulus negatives improved specificity but reduced rest AUC
Source of the 15 archived ds006253 feature files (inputs/).