sciscape Publications
← All publications

An offline noise rule saved calibration pulses and raised mean SEEG forecast error in eight sessions

We tested an offline rule that stops SEEG calibration after three to five pulses at each stimulation site. We used OpenNeuro ds004696 version 1.0.1: eight patient sessions, 86 sites, and 886 bipolar readouts. The rule used 353 pulses instead of 430. It saved 17.9 percent of the pooled total and 20.5 percent on the equal-patient average. It stopped before five at 41 sites. Mean normalized error on later individual pulses rose from 0.63669 with five pulses to 0.65837. A random permutation of the chosen pulse counts held each patient pulse budget equal. Its exact expected mean error was 0.67312. The rule gained 0.01475 against this reference; the primary two-sided patient sign-flip p value was 0.0625. This gain remains uncertain. All fixed response-window checks saved pulses and raised mean error relative to five pulses. Test pulses followed calibration within each site, but site times interleaved across every session. Source-good pulse labels were retrospective. These results do not establish live interface performance. The package preserves the fixed local plan, exact matrices, all decisions, figures, source recipes, and code. Complete public source rebuilds matched three patients. A separate replay matched all numerical files and PNG figures. This is a new analysis of a previously used cohort, not new recordings or an independent replication.

SEEG · electrical stimulation · brain-computer interface · calibration · pulse allocation · forecast error · noise rule · offline analysis

Admitted 3 citing publications

References

3
  1. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    We used the corrected pulse product matrices for eight patients, 86 stimulation sites, and 886 bipolar readouts. We also used the source metadata, extraction code, and source hashes. These inputs enabled a new sequential pulse rule and an exact pulse-budget comparison. We rebuilt the complete compact data for patients 01, 05, and 08 from public sources and reproduced their file hashes.

  2. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    Analyzed source data: OpenNeuro ds004696, version 1.0.1, recorded in the cached exact-version metadata.

  3. doi:10.1523/JNEUROSCI.2201-22.2023

Cited by

3 publications

Public catalog entries on Sciscape.