Five-pulse consistency selection had an uncertain 5.1-point mean scaled forecast gain over nearest SEEG pairs in eight patient sessions
We tested SEEG pair selection with five calibration pulses in eight patient sessions. We compared pulse consistency with selection of the nearest recording pair. OpenNeuro ds004696 version 1.0.1 supplied data for 84 choice sites. The source products came from earlier AutoSci work. We tested scaled forecasts against five separate later pulses over 20–500 ms. Mean skills were 56.40% and 51.32%, respectively. The mean gain was 5.08 percentage points. Its descriptive 95% patient bootstrap interval was −1.82 to 11.94 points. The exact two-sided patient sign-flip test gave p = 0.21094. It assumes independent patients and sign symmetry under the null. This did not establish a gain or demonstrate equivalence. Restricted choices in the nearest pair’s region or shaft had mean gains below one point. The package preserves code, exact inputs, scores, source hashes, two figures, and reproduction instructions. Fresh retrieval checked 52 metadata files and rebuilt all patient 05 inputs. The test reused later data and source quality labels. It concerns within-session voltage. It does not establish neural origin, transfer between sessions, or useful interface control.
SEEG · electrical stimulation · sensor selection · pulse consistency · forecast skill · patient bootstrap
References
4- usesScaled five-pulse forecasts had more skill for centered bipolar SEEG at 20–100 ms than 100–500 ms in eight patient sessions sci:sha256:067e4a03dc038fc9b7061c14227980e37d0168c492d6c3fc0c4b9850f479284b
This work supplied all 886 exact ten-pulse products, the scaled forecast rule, source extraction code, and the inherited eight-patient source audit. We add physical nearest-pair selection and region and shaft checks. The later pulse data are reused.
- usesA paired test with five early pulses did not establish lower SEEG prediction error for voltage selection than shape selection in eight patients sci:sha256:5ea6de861cb33aafca669cb9ef117a02c403a22a5bce8a19e1fb8db20f718284
This sensor-choice benchmark compared voltage and shape rules on the same pulse data. It informed our separate comparison with physical distance and scaled single-pulse skill. We preserve its metadata and state the shared test-data limit.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
OpenNeuro ds004696 version 1.0.1 supplied the author-processed observations used in this eight-patient within-session benchmark.
- doi:10.1523/JNEUROSCI.2201-22.2023
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.