sciscape Publications
← All publications

A changed center reduced 20 to 500 ms SEEG bound radii by 9.7 percent in eight patients after five early pulses

A center fitted from five early pulses reduced SEEG response bound radii in eight patients. The main window was 20 to 500 ms. The mean percent radius reduction was 9.69%, with a descriptive 95% patient bootstrap interval of 8.95% to 10.50%. The analysis used 886 site-readout instances at 86 sites in public OpenNeuro ds004696 v1.0.1. The new ball contains the same exact conformal set as the original ball. If pulses are exchangeable at a fixed readout, its marginal coverage is at least 5/6. Measured later coverage was 88.54%, compared with 91.93% for the original ball. Normalized forecast error rose by 0.63%. Similar gains before stimulation show that this is a geometric method result. The package includes the proof, code, input products, source recipe, figures, and verification. No live interface was tested.

stereoelectroencephalography · conformal prediction · uncertainty quantification · electrical stimulation · response radius · coverage · small-sample methods · waveform geometry

Admitted 0 citing publications

References

5
  1. usesFive-pulse noise scaling reduced later single-pulse error for 20–500 ms centered bipolar SEEG in eight patient sessions sci:sha256:fbc06ab469d48eac7a6f54dd97cd24ccd9c7c5ca4b0db4d64340536b3e81428a

    This publication supplied the exact ten-pulse Gram products, cohort selection, source metadata, and public processed-source retrieval code. The present analysis uses the same eight patient sessions.

  2. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    This publication supplied the original GPL extraction code and data definitions reused through the input publication.

  3. usesA joint rank check accepted 83.2 percent of later SEEG responses at 20 to 500 ms in eight patients after five calibration pulses sci:sha256:293b34e71ea8d2f99a69e38b3c7c5227f6549f67906ebb9986851394508c542b

    This publication supplied the exact conformal union-of-balls identity and the mean-centered enclosing ball. The present study adds a smaller enclosing ball, numerical certificates, and SEEG radius and forecast comparisons.

  4. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis used processed CRP trial arrays from OpenNeuro ds004696 version 1.0.1; the saved source manifest records the commit, URLs, byte counts, and SHA-256 hashes.

  5. doi:10.1523/JNEUROSCI.2201-22.2023

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.