Absolute distance had no clear mean AUC gain over the label gap for absent conditions at four SEEG pairs in an offline test of eight patients
We tested two scores for responses from a stimulation condition absent from the fit and calibration data. The source was public STReEF SEEG data from eight patients. Each patient supplied four conditions. Each fold used three known templates, four bipolar recording pairs, and voltage from 20 to 100 ms after a pulse. Absolute distance gave a mean detection AUC of 0.648. The label gap gave 0.635. The mean difference was 0.013, with a descriptive 95% patient bootstrap interval from -0.089 to 0.113. This is no clear mean gain. At separate cutoffs that accepted five of six calibration pulses, distance accepted 38.8% of absent test pulses and the gap accepted 59.4%. Distance also gave fewer correct known outputs: 46.5% of offered known pulses, compared with 60.8%. Before-pulse control scores were near chance. The test has an offline scope, a reused cohort, dependent fold evaluations, and contact order confounded with time. It does not establish device performance. The package preserves source pins, features, native byte examples, models, pulse decisions, three figures, code, and reproduction instructions. Fresh source retrieval, metadata checks, independent numerical checks, and full result reproduction passed.
stereoelectroencephalography · brain-computer interface · absent-condition detection · novelty detection · area under the curve · offline evaluation
References
7- usesThe nearest half of SEEG pairs had a higher mean rate of repeatable waveforms across recorded contact order reversal in eight STReEF patients sci:sha256:399c1198c4184a27bd9be26923336885a19d4fdd7d9a5d49a4ca8f9cffac5cae
Uses the source selection rule and pinned raw retrieval helpers that came through the direct parent. They provide the eight-patient SEEG source sample and its data provenance.
- usesA template gap gave 0.827 mean error AUROC across known sites in five offline SEEG sessions at 20 to 100 ms sci:sha256:dc63492a24a9ea283c3614ac0cb44e52c40919816b33c87d0a619dfb6a649bb8
Uses the concept of a matched comparison between template distance and a label gap. The present test concerns absent conditions in a different dataset. It does not reuse this source numerical result.
- usesA learned gate accepted most SEEG responses from excluded shafts in five offline sessions with two template pulses sci:sha256:620409f7d19aadb1bb9efa3db4388383b492d813e6e6d50f324126df0a963937
Uses the absent-condition rejection test and the offline timing audit as test concepts. The present score comparison uses a different dataset and condition definition.
- usesSelection for distinct response patterns had an uncertain mean accuracy gain at four SEEG pairs in eight STReEF patients sci:sha256:143d7f91f05a486692072b6c1e61b67efa46729f12681baae0430cec9016d9ad
Uses the fixed four-condition sample, voltage features, source metadata, native byte examples, and retrieval code. These inputs permit a matched score comparison with no voltage from the absent condition in fitting or calibration.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
Source dataset used: STReEF OpenNeuro ds005448, version 1.0.0; the saved source metadata records this exact version DOI and CC0 license.
- doi:10.1016/j.ynirp.2025.100274
- doi:10.1007/s12021-022-09567-6
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.