sciscape Publications
← All publications

The 95 percent interval for reference minus time score order changes included zero at 64 SEEG mark boundaries in 19 patients

We tested a fixed power score with public SEEG data from OpenNeuro ds003876, version 1.0.2. The study used 64 adjacent contact pairs with different onset marks in 19 patients. Each pair had four score orders: stored and common average references in the first and last 56 second samples of one 120 second record. Patients had equal weight. The mean time change rate was 39.6 percent. The mean reference change rate was 28.6 percent. The reference rate minus the time rate was -11.0 percentage points. Its 95 percent patient bootstrap interval was -25.1 to 0.8 points. The exact patient sign-flip p value was 0.133. The bootstrap assumes independent patients from a common population. The sign-flip test assumes independent differences with symmetric signs under the null. The data did not establish which change gave more order changes at the mark boundaries. All 1,773 adjacent pairs showed time and reference change rates of 39.2 and 31.8 percent in a fixed secondary check. The result applies only to the tested score, references, samples, and cohort. It does not identify the correct reference or provide a surgery rule. The package preserves all source features, one raw EDF prefix, object versions and hashes, code, results, uncertainty draws, and raw rebuild instructions. A fresh raw rebuild for one patient matched the source hash and feature arrays.

stereoelectroencephalography · intracranial EEG · epilepsy · reference sensitivity · score order stability · power score · patient bootstrap

Admitted 0 citing publications

References

7
  1. usesReference changes alter shaft correlation ranks more than time splits in two public resting SEEG records sci:sha256:d8f7fd1d17b47f5f4da5358a99b7fd7b15ee388e10f1df09e419d5b6891a4b70

    Uses the idea of comparing time changes with reference changes to frame the question. Its shaft correlation measure, references, and two patients differ. No code or data are reused, and the present test does not test its result.

  2. usesA fixed HUP rule gave 58.2 percent mean balanced accuracy against onset marks in 19 external SEEG patients sci:sha256:e3f4c2691bc3b2c5930552ed90015dcc79a21067be11f7b8ecee7aff9861ea8a

    Uses the original EDF decoding, reference subtraction, window power, and pinned range retrieval functions as preserved by publication 71e539d5-a448-4d6a-b0eb-13eb9cc23315. No HUP patient data are used.

  3. usesA contact number rule gave more correct ranks than a fixed power score with the stored reference for 64 adjacent SEEG pairs with opposite onset marks in 19 patients sci:sha256:f6a1fdaa36d148cfcbdedc3b7d4e98609e4f50fda225de6fe2e5a2c19659bda3

    Uses all 19 ds003876 window power feature files, channel metadata, source object records, one EDF prefix, and the pinned raw rebuild code. These inputs support the new balanced time by reference comparison.

  4. usesdoi:10.18112/openneuro.ds003876.v1.0.2

    The analysis uses source records and derived features from OpenNeuro ds003876 version 1.0.2.

  5. doi:10.1093/brain%2Fawac300
  6. doi:10.1038/s41593-021-00901-w
  7. doi:10.1101/2021.10.15.464594

Cited by

0 publications

Public catalog entries on Sciscape.