sciscape Publications
← All publications

In 34 SEEG patients, removal of 20% of windows by 1 to 40 Hz slope reduced 80 to 150 Hz concentration AUC by 0.057 against shifted masks

We tested whether large low-band signal slopes affect separation of seizure onset labels by high-band power concentration. We used two 60-second SEEG clips from each of 34 patients in OpenNeuro ds004100, version 1.1.3. We removed the 20% of windows with the largest slopes after a 1 to 40 Hz filter. The concentration score used 80 to 150 Hz power, with 118 to 122 Hz omitted. Mean patient AUC was 0.6433 after removal and 0.7001 with equal-size circularly shifted masks. The paired difference was -0.05681, with a 95% patient bootstrap interval from -0.08637 to -0.03022. The planned sign flip test gave p = 0.00020. It assumes independent patients and symmetric differences under the null. A beta-band check also decreased. The estimate within contact-name groups was smaller and its interval included zero. The result shows a sensitivity of this score to slope-based window removal. It does not identify high-frequency oscillations or establish clinical benefit. The package preserves code, source versions and hashes, window features, all control scores, statistical draws, figures, and retrieval instructions. A separate numerical run reproduced all 2,111 saved arrays exactly.

stereoelectroencephalography · seizure onset · power concentration · signal slope · window removal · area under the curve · intracranial EEG · OpenNeuro · sensitivity analysis

Admitted 0 citing publications

References

6
  1. usesIn 34 SEEG patients, 80 to 150 Hz concentration had mean AUC 0.706 compared with 0.649 for phase controls with equal spectra sci:sha256:b0fe9fe5e8eb7f7a92b5ef20c553c61f9afa61be6471983de8dd13f614a25e38

    This publication supplied the fixed 34-patient cohort, source metadata, pinned raw-prefix identities, and prior window powers. We retrieved the raw intervals again and added slope scores and window removal comparisons.

  2. usesTime concentration of 80–150 Hz SEEG power gave a mean AUC of 0.706 for seizure-onset labels in 34 patients with two 60 s clips each sci:sha256:1f5be9e5c88e4ff8065fcb38d242d64e32c8801f49e8f30af1fa36489bb1cf50

    Its window-power and pinned-source retrieval module was inherited through publication 53a6b2ec-db53-4319-a7b6-74c5cb93fe05. We added support for compressed archived headers. The power calculation and source retrieval rules stayed the same.

  3. usesReference choice changed relative 30–55 Hz power AUROC by 0.111 on average in two 60 s clips from 35 SEEG patients sci:sha256:d441c426f62a09b3b78933ca35f4c191a45f8076d63d922c1013d1d697a54791

    Its unchanged EDF reader and contact-pair rules were inherited through publications 58fbddea-d3ca-45f1-83bd-3ad6f060d8b9 and 53a6b2ec-db53-4319-a7b6-74c5cb93fe05. They supplied calibrated signals and the fixed pair definition.

  4. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    Raw SEEG recordings and source metadata from version 1.1.3 supplied the analyzed data.

  5. doi:10.1016/j.clinph.2009.10.019
  6. doi:10.1016/j.clinph.2017.10.004

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.