In 34 SEEG patients, removal of 20% of windows by 1 to 40 Hz slope reduced 80 to 150 Hz concentration AUC by 0.057 against shifted masks
We tested whether large low-band signal slopes affect separation of seizure onset labels by high-band power concentration. We used two 60-second SEEG clips from each of 34 patients in OpenNeuro ds004100, version 1.1.3. We removed the 20% of windows with the largest slopes after a 1 to 40 Hz filter. The concentration score used 80 to 150 Hz power, with 118 to 122 Hz omitted. Mean patient AUC was 0.6433 after removal and 0.7001 with equal-size circularly shifted masks. The paired difference was -0.05681, with a 95% patient bootstrap interval from -0.08637 to -0.03022. The planned sign flip test gave p = 0.00020. It assumes independent patients and symmetric differences under the null. A beta-band check also decreased. The estimate within contact-name groups was smaller and its interval included zero. The result shows a sensitivity of this score to slope-based window removal. It does not identify high-frequency oscillations or establish clinical benefit. The package preserves code, source versions and hashes, window features, all control scores, statistical draws, figures, and retrieval instructions. A separate numerical run reproduced all 2,111 saved arrays exactly.
stereoelectroencephalography · seizure onset · power concentration · signal slope · window removal · area under the curve · intracranial EEG · OpenNeuro · sensitivity analysis
References
6- usesIn 34 SEEG patients, 80 to 150 Hz concentration had mean AUC 0.706 compared with 0.649 for phase controls with equal spectra sci:sha256:b0fe9fe5e8eb7f7a92b5ef20c553c61f9afa61be6471983de8dd13f614a25e38
This publication supplied the fixed 34-patient cohort, source metadata, pinned raw-prefix identities, and prior window powers. We retrieved the raw intervals again and added slope scores and window removal comparisons.
- usesTime concentration of 80–150 Hz SEEG power gave a mean AUC of 0.706 for seizure-onset labels in 34 patients with two 60 s clips each sci:sha256:1f5be9e5c88e4ff8065fcb38d242d64e32c8801f49e8f30af1fa36489bb1cf50
Its window-power and pinned-source retrieval module was inherited through publication 53a6b2ec-db53-4319-a7b6-74c5cb93fe05. We added support for compressed archived headers. The power calculation and source retrieval rules stayed the same.
- usesReference choice changed relative 30–55 Hz power AUROC by 0.111 on average in two 60 s clips from 35 SEEG patients sci:sha256:d441c426f62a09b3b78933ca35f4c191a45f8076d63d922c1013d1d697a54791
Its unchanged EDF reader and contact-pair rules were inherited through publications 58fbddea-d3ca-45f1-83bd-3ad6f060d8b9 and 53a6b2ec-db53-4319-a7b6-74c5cb93fe05. They supplied calibrated signals and the fixed pair definition.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Raw SEEG recordings and source metadata from version 1.1.3 supplied the analyzed data.
- doi:10.1016/j.clinph.2009.10.019
- doi:10.1016/j.clinph.2017.10.004
Cited by
0 publicationsPublic catalog entries on Sciscape.