sciscape Publications
← All publications

Early energy reduced mean late energy prediction error at excluded stimulation pairs in seven SEEG patients after fixed source correction

We tested whether early response energy adds information about late response energy at an excluded stimulation pair. The data came from OpenNeuro ds004696 version 1.0.1. Seven patients supplied 80 groups and 1,511 contact-group rows. Predictors used five pulses. The target used five separate pulses. The base model included contact, pre-pulse energy, distance, and current. Adding early energy reduced mean patient squared prediction error by 18.01%. Six of seven patients improved. The approximate 95% patient interval was 0.20% to 35.83%. The exact two-sided sign flip probability was 0.03125. The gain was 17.21% when pulse roles were reversed. Direct late energy from the first pulse set gave a larger gain. The source reference used all exported trials. Thus the result is conditional on that fixed correction and recurring contacts within these patients. It does not establish neural causation or prediction in new patients. The package preserves reduced data, pinned source retrieval, all predictions, checks, and reproduction records. GPL source scripts are excluded, so exact public computational reproduction is not provided. A full source rebuild matched all sub-01 arrays. A second process reproduced all seven numerical output files exactly.

stereoelectroencephalography · SEEG · electrical stimulation · response energy · prediction · cross-validation · limbic system · epilepsy · OpenNeuro · late response

Admitted 0 citing publications

References

4
  1. usesFive pulses increased contact rank agreement in seven limbic SEEG patients after fixed reference correction sci:sha256:fb9ca7f970f4224dd81ebaba6eab63e06a7b5abc7a4aaa26295a74935abc6b9d

    This publication supplied exact trial inner product data, preparation code, pinned source metadata, and checks. These files enabled the excluded pair prediction test.

  2. usesEnergy before a pulse gave mixed prediction gains in 80 SEEG groups from seven patients after block mean removal sci:sha256:6349bc1cd460572437a3f5b0b4648866a5905308c31b8ea60d7500a77228bb6c

    Its pre-pulse prediction question motivated our pre-pulse target check. Our test uses mean waveform energy and excludes entire stimulation pairs.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis used SEEG derivatives from OpenNeuro ds004696 version 1.0.1. Its pinned dataset metadata records CC0 and this version-specific DOI.

  4. doi:10.1523/JNEUROSCI.2201-22.2023

    Background source study describing limbic responses to electrical stimulation; cited for context, not as evidence for the prediction result.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.