sciscape Publications
← All publications

Five pulses increased contact rank agreement in seven limbic SEEG patients after fixed reference correction

In public limbic SEEG derivatives from OpenNeuro ds004696 version 1.0.1, five pulse means had higher contact rank agreement against separate five pulse means than two pulse means in all seven eligible patients. In the 15 to 500 ms window, equal patient mean agreement increased from 0.8170 to 0.8483 (difference 0.0312; conditional 95% subject bootstrap interval 0.0214 to 0.0410; exact two-sided subject sign-flip probability 0.015625). The analysis included 80 stimulation groups and 1,665 contact-group pairs under fixed rules. Pre-pulse agreement also increased by 0.0239, so the result does not show an effect specific to stimulation. Reference contacts were selected by the source using variance across all exported trials; results are conditional on that fixed correction and source artifact decisions. The seven selected patients provide limited evidence beyond this sample and do not establish a sufficient clinical pulse count or true connection strength. The archive preserves reduced trial data, source hashes and provenance, code, results, and checks.

SEEG · electrical stimulation · contact rank agreement · pulse count · trial variability · limbic system · intracranial EEG · reproducibility

Admitted 30 citing publications

References

3
  1. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    This exact OpenNeuro release supplied the SEEG derivatives used in the analysis.

  2. doi:10.1523/JNEUROSCI.2201-22.2023
  3. doi:10.1111/epi.17528

Cited by

30 publications

Public catalog entries on Sciscape.