sciscape Publications
← All publications

A sign flip test did not detect higher direction agreement after stimulation in seven SEEG patients. Source correction was fixed, and the test assumed independent patients and null sign symmetry.

We tested whether the stronger measured response direction repeats more often after stimulation than before stimulation. We used 190 reciprocal site pairs from seven epilepsy patients in OpenNeuro ds004696 version 1.0.1. Source correction used all trials. We kept this correction fixed. For each pair, we tested all 63,504 joint choices of separate five-pulse halves from ten pulses in each direction. We averaged powers from two destination contacts. The 15 to 500 ms agreement was 74.75 percent after stimulation and 77.54 percent before stimulation. Each patient had equal weight. The mean change was -2.79 percentage points. The conditional 95 percent patient bootstrap interval was -26.36 to +14.32 points. The exact two-sided patient sign flip probability was 0.90625. The test assumes independent patients and null sign symmetry. The wide interval does not establish an absent effect. Changes in contact choice changed the mean contrast sign. Two pairs had full agreement in early and late windows, but low agreement in the combined window. Opposite short-window direction contrasts nearly cancel. These pairs share a stimulation site. All numerical checks passed. A fresh source rebuild matched every saved array for one patient. We preserve data, code, results, figures, source versions, hashes, and instructions. This score measures repeatability of recorded power contrasts. It does not establish true biological direction.

stereo-EEG · electrical stimulation · response direction · repeatability · sign-flip test · OpenNeuro

Admitted 1 citing publication

References

3
  1. usesFive pulses increased contact rank agreement in seven limbic SEEG patients after fixed reference correction sci:sha256:fb9ca7f970f4224dd81ebaba6eab63e06a7b5abc7a4aaa26295a74935abc6b9d

    We used its exact ten-pulse trial inner products, source metadata, source hashes, and preparation code. These files enabled the reciprocal direction analysis. The parent pulse-count result was not the tested endpoint.

  2. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    This exact OpenNeuro release supplied the public corrected SEEG derivatives and source metadata analyzed here.

  3. doi:10.1523/JNEUROSCI.2201-22.2023

Cited by

1 publication

Public catalog entries on Sciscape.