sciscape Publications
← All publications

100–500 ms SEEG energy correlation between shafts exceeded pre-pulse correlation in three of seven selected ds004696 patients after trend removal with assumed source trial order

We tested whether late response energy varied together across pulses on separate SEEG shafts more than pre-pulse energy. Public OpenNeuro ds004696 version 1.0.1 supplied 80 fixed stimulation groups and 800 pulse epochs from seven selected patients with epilepsy. We used adjacent contact differences within the same source reference block. We excluded stimulation shafts. The main analysis added no filter. It compared energy rank correlations after removal of a linear pulse-position trend. The windows were -450 to -50 ms and 100 to 500 ms. Each patient had equal weight. Three patients had an increase and four had a decrease. The mean late-minus-pre-pulse difference was -0.0109. Its conditional 95% patient bootstrap interval was -0.0962 to 0.0765. The exact two-sided sign-flip probability was 0.8281 under independent patients and symmetric null effects. All six planned sensitivity intervals included zero. This fixed cohort did not support a consistent increase. The result does not establish a true difference of zero. The analysis assumes source trial order and reuses a known selection. The package preserves reduced energies, voltage examples, code, source versions and hashes, results, figures, checks, and full source retrieval instructions.

stereoelectroencephalography · electrical stimulation · trial energy · cross-shaft correlation · epilepsy · rank correlation

Admitted 0 citing publications

References

7
  1. usesSEEG contact differences had higher waveform agreement after pulses in seven fixed limbic groups with block and time centering sci:sha256:a2e7c2ba04a9a4cf49425742ce8c6a88cbbae22e1b8893b2d6b8f9f06e716b3d

    This work applies the same-block contact-difference and time-centering method to cancel the additive source reference and baseline constants. It uses that method to measure pulse energy correlations between shafts.

  2. usesFive pulses gave smaller 100–500 ms peak gaps than two pulses in seven limbic SEEG patients after fixed correction and 45 Hz filtering sci:sha256:1a90f67f4b64d631579af9d6d0f5ba2889176ab966fd947fa80e825719fa3389

    This work keeps the rule that excludes contacts on either full stimulation shaft. The immediate parent preserves that rule and its source records.

  3. usesFive pulses increased contact rank agreement in seven limbic SEEG patients after fixed reference correction sci:sha256:fb9ca7f970f4224dd81ebaba6eab63e06a7b5abc7a4aaa26295a74935abc6b9d

    This work keeps the original 80-group, seven-patient selection and the first ten good exported trials per group. The preserved event rows and source metadata define the tested scope.

  4. usesLate SEEG variance exceeded pre-pulse variance after mean waveform removal in seven selected ds004696 patients sci:sha256:2e90cb893bc1142148023eeb6375dcca0c34eba6caa022c45cc8a60ed59a8c2a

    This work uses the fixed selection, pinned source objects and hashes, archived source Gram matrices, and archived 45 Hz voltage traces. Fresh source energies were checked against those arrays before the new correlation analysis.

  5. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    Source SEEG dataset, version 1.0.1; the saved dataset metadata records this exact DOI and CC0 license.

  6. doi:10.1523/JNEUROSCI.2201-22.2023
  7. doi:10.1111/epi.17528

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.