Mean relative energy change was -0.275 dB between selected three-pulse blocks in seven SEEG patients with fixed source correction
We compared selected good pulses 1 to 3 with pulses 8 to 10 in public SEEG data. Seven patients supplied 80 stimulation groups and 1,665 contact-group responses. We tested post-pulse log energy change relative to pre-pulse log energy change. The method took contact medians, equal group means, and equal patient means. The mean change was -0.275 dB. Its 95% Student t interval was -0.705 to +0.155 dB. An exact patient sign flip test gave p = 0.1875. That test assumes independent patients and symmetric null contrasts. The interval also assumes normal patient contrasts. Four patients had negative changes and three had positive changes. The test did not establish a common decrease or absence of change. A later comparison of four averaging rules gave negative mean estimates but different patient signs and uncertainty. The five-pulse contact mean reproduced an earlier result from the same cohort. This is not an independent patient replication. The package includes code, 66,600 event-linked trial energy values, source hashes, audit results, and reproduction instructions. The result applies to selected good pulses and fixed source correction. It does not identify neural adaptation.
stereoelectroencephalography · electrical stimulation · pulse order · voltage energy · brain networks · repeated measures
References
6- usesA sign flip test did not detect a larger pulse order ratio after stimulation in seven limbic SEEG patients under independent symmetric null effects sci:sha256:cfe5decab9ef6dedbce2064ab74781918b6bc93c616274990bc447060bc20894
The waveform pulse order study informed interpretation of the energy result. Its statistic measures trace shape and agreement in the same cohort. We cite it to distinguish the tested statistics and their limits.
- The mean response to baseline energy ratio fell between two sets of five good pulses in seven limbic SEEG patients with fixed source correction sci:sha256:d2231d39e746533fbfa827e77629d804cbb8c4eca8632f4af278e0d60c259800
[Legacy relation: reproduces] The later five-pulse contact mean comparison reproduced all seven archived patient energy changes within 2.3e-16 dB. It used the same patients and inputs, so it is not an independent patient replication.
- usesFive pulses increased contact rank agreement in seven limbic SEEG patients after fixed reference correction sci:sha256:fb9ca7f970f4224dd81ebaba6eab63e06a7b5abc7a4aaa26295a74935abc6b9d
This publication supplied the exact trial inner product matrices, voltage examples, selection records, source event metadata, source hashes, and retrieval method. We used these inputs to calculate individual trial energy changes.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
This is the exact OpenNeuro dataset version used for the SEEG data.
- doi:10.1523/JNEUROSCI.2201-22.2023
- doi:10.1111/epi.17528
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.