Energy mean times reduced repeat gaps more before than after limbic stimulation in seven SEEG patients with fixed correction and 45 Hz filtering
We compared energy mean times with largest absolute peak times in public SEEG data. The source was OpenNeuro ds004696, version 1.0.1. We used 80 limbic stimulation groups from seven patients with epilepsy. The test used ten pulses per group, fixed source correction, and a 45 Hz filter. We compared two separate five-pulse means in all 126 distinct partitions. The energy mean reduced repeat gaps by 27.23 ms after stimulation and 81.38 ms before stimulation. The paired patient mean difference was −54.15 ms. Its conditional 95% patient bootstrap interval was −67.34 to −38.39 ms. All seven patient differences were negative. The exact two-sided sign-flip probability was 0.015625 under patient independence and null symmetry. Four fixed checks kept the same mean direction. An independent implementation checked all 1,528,128 primary timing values. Twelve numeric files matched byte for byte in a fresh process. One full pinned source file was retrieved and rebuilt with exact array matches. A later proof showed that independent Gaussian samples give the energy time 1/52 of peak-time variance on a 102-sample grid. This proof is not a model of filtered SEEG. Smaller repeat gaps alone did not establish more accurate neural timing. The package preserves code, voltage windows, source versions, results, figures, and reproduction instructions.
stereoelectroencephalography · SEEG · limbic stimulation · energy mean time · peak time · repeatability · Gaussian noise · signal processing
References
4- usesFive pulses gave smaller 100–500 ms peak gaps than two pulses in seven limbic SEEG patients after fixed correction and 45 Hz filtering sci:sha256:1a90f67f4b64d631579af9d6d0f5ba2889176ab966fd947fa80e825719fa3389
This publication supplied the fixed voltage windows, retained contact selection, source versions, metadata, and source reconstruction code. We used them to compare energy mean times with absolute peak times.
- usesFive pulses increased contact rank agreement in seven limbic SEEG patients after fixed reference correction sci:sha256:fb9ca7f970f4224dd81ebaba6eab63e06a7b5abc7a4aaa26295a74935abc6b9d
This publication supplied the upstream eligible group selection. We kept its cohort through the immediate parent and then used the parent's contacts outside stimulation shafts.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The analysis used corrected MATLAB epochs from OpenNeuro ds004696, version 1.0.1.
- doi:10.1523/JNEUROSCI.2201-22.2023
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.