sciscape Publications
← All publications

One pair per shaft showed no clear gain in lowest balanced accuracy after a known simulated shaft loss in eight later-trial SEEG tests at 16 contacts

Eight public SEEG recordings tested whether one pair per shaft preserves accuracy after a known shaft loss. Both panels used eight pairs, 16 distinct contacts, and 24 power features. The mean lowest balanced accuracy changed from 64.7% to 65.6%. The paired change was +0.9 points, with a descriptive 95% person-bootstrap interval of -2.0 to +3.3 points. Intact accuracy changed by -0.1 points. The package includes an exact additive selector, independent checks, features, models, fault scores, source hashes, and figures. The test uses later event-aligned trials from the same clinical recordings, known simulated faults, and a previously used cohort. It is exploratory and does not test continuous intent detection or stimulation.

stereoelectroencephalography · brain-computer interface · fault tolerance · balanced accuracy · bipolar electrodes · feature selection

Admitted 9 citing publications

References

5
  1. usesContact reuse did not show a mean accuracy gain at an eight-contact limit in later trials from eight SEEG recordings sci:sha256:5521afe57746cb6416438c0681dc8b9a3265fe030839a5954b4f5d947edc95e4

    The fixed contact comparison helped define our equal-budget constraint. We wrote a new exact selector that combines contact-disjoint pairs with per-shaft limits.

  2. usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd

    We use all saved trial features, exclusions, source metadata, raw audit ranges, and unchanged retrieval code. We reproduce the intact eight-pair scores. The new test compares shaft limits at the same 16-contact budget.

  3. usesEight-pair SEEG reserve decoders gave 61.7% mean balanced task accuracy after simulated loss of all primary shafts in eight recordings sci:sha256:3c2cc13a3310a10095ea01ce382c47a1a29f11644ef5afdfa7dae05c09bd9eb9

    The separate-shaft reserve test helped define the shared shaft failure question. Our test removes one shaft at a time and holds the primary contact and feature counts equal.

  4. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    Source dataset, OpenNeuro ds004473 version 1.0.2; the preserved dataset metadata hash matches this version.

  5. doi:10.1088/1741-2552%2Facae0a

Cited by

9 publications

Public catalog entries on Sciscape.