sciscape Publications
← All publications

Whole-shaft training showed no clear gain over matched pair omission in lowest balanced accuracy after known shaft loss with mean replacement on later trials from eight SEEG recordings

Whole-shaft training showed no clear gain over matched pair omission under known simulated shaft loss. We used eight recordings from public SEEG dataset ds004473, version 1.0.2. Each reader used eight pairs and three power bands. Earlier trials trained the reader. Later trials tested it. Training means replaced missing log-power features. The primary training omission probability was 0.5. The exact control matched the omitted-pair count distribution and each pair's marginal omission rate. The mean lowest balanced accuracy was 65.24% for shaft training and 65.29% for matched training. The paired change was -0.05 percentage points. The person-bootstrap 95% interval was -0.62 to 0.47 points. The exact two-sided sign-flip p value was 0.9375. Mean intact accuracy was 70.89% and 70.66%, respectively. No reader gave a constant class in any tested shaft-loss case. A full raw rebuild matched all 3,133,395 stored power values and all 2,032 used range hashes. The package preserves data, code, masks, readers, predictions, figures, provenance, and instructions. This reused cohort gives exploratory evidence for offline reading. It does not test stimulation or a live interface.

stereoelectroencephalography · SEEG · brain-computer interfaces · signal loss · logistic regression · robustness · balanced accuracy

Admitted 2 citing publications

References

5
  1. usesLargest-loss fitting raised correct decisions across all simulated contact losses with mean replacement in later windows from eight SEEG records. Intact accuracy fell. sci:sha256:de4d668b2ff11fa38535be51f1bf366adeaefbfd31573f20931c952f35229f22

    The cited class-recall audit motivates constant-class checks and reports of both class recalls.

  2. usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd

    This study uses its feature data, trial rules, extraction code, and training-only pair score.

  3. usesOne pair per shaft showed no clear gain in lowest balanced accuracy after a known simulated shaft loss in eight later-trial SEEG tests at 16 contacts sci:sha256:5f8c5a234d2daf29596b053b0c7a1a1f7aac5fdbdaf43faeac64da4b037739ad

    This study tests training masks after the cited study tested shaft limits during pair selection.

  4. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The analysis uses the eight recordings from OpenNeuro ds004473, version 1.0.2.

  5. doi:10.1088/1741-2552%2Facae0a

Cited by

2 publications