sciscape Publications
← All publications

Adding time concentration did not increase mean same-shaft label AUC in fixed 80 to 150 Hz models tested on 30 SEEG patients

We tested whether time concentration adds clinical seizure onset label ordering beyond mean power. The source was OpenNeuro ds004100 version 1.1.3. Each of 30 patients supplied two 60 s SEEG clips. Power used 80 to 150 Hz, with 118 to 122 Hz omitted. Concentration was the fraction of summed one-second power in the six largest of 60 windows. Training excluded the tested patient. The fixed models used pairwise logistic loss and an L2 penalty of 0.1. Comparisons used positive and other pairs on the same named shaft. Patients had equal mean weight. Baseline mean AUC was 0.8296. Added-model mean AUC was 0.8279. The difference was -0.0017. Its 95 percent patient bootstrap interval was -0.0219 to +0.0110, with all models fitted again in each of 2,000 samples. This approximate interval assumes independent patients and representative patient sampling. The test did not detect a mean gain. It does not prove equal performance. Planned checks without shared contacts and with contact number gave similar small negative estimates. The study extends prior work in the same cohort. It does not test surgical outcomes or an external cohort. All 68 input feature files matched a fresh extraction from 72 pinned raw ranges. Independent reader and model checks passed. The package preserves data, source versions, hashes, code, scores, bootstrap identities, figures, failure logs, and reproduction commands.

stereoelectroencephalography · SEEG · epilepsy · time concentration · high-frequency power · same-shaft comparison · patient bootstrap · AUC

Admitted 1 citing publication

References

3
  1. usesTime concentration of 80–150 Hz SEEG power gave a mean AUC of 0.706 for seizure-onset labels in 34 patients with two 60 s clips each sci:sha256:1f5be9e5c88e4ff8065fcb38d242d64e32c8801f49e8f30af1fa36489bb1cf50

    This publication supplied the 68 window-power arrays, clinical labels, source metadata, pinned raw retrieval records, and extraction code. These inputs enabled the fixed test of concentration beyond mean power. A fresh source rebuild checked all arrays.

  2. usesMean high gamma AUC exceeded beta AUC by 0.077 on matched shafts in 30 patients with 30-second SEEG samples sci:sha256:3ac0ff83c7e73ba0f38e41d06237d9e19ba5215b7cdf9ca6b59b5a4f0ac96059

    This publication informed the use of SOZ-control comparisons on the same named shaft. The present test uses different signal windows and equal positive-pair weights. Its features and results were not used as inputs.

  3. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The analysis uses OpenNeuro ds004100 version 1.1.3 as its source dataset; the saved dataset metadata identifies this exact version and provides the DatasetDOI and CC0 license.

Cited by

1 publication

Public catalog entries on Sciscape.