sciscape Publications
← All publications

After calibration and model fitting, two-bit power features gave 71.2% mean balanced accuracy in eight later-trial SEEG tests

We tested a fixed two-bit code for 24 extracted SEEG log-power features in all eight recordings from OpenNeuro ds004473 version 1.0.2. Each decoder used eight training-selected bipolar pairs. Encoder limits and model fits used only early trials. On 674 later trials, mean balanced accuracy was 71.2% with two-bit features and 70.7% with original float32 features. Each patient had equal weight. The paired change was +0.53 percentage points. Its 95% patient bootstrap interval was -0.87 to +1.85 points. The exact patient sign-flip test gave p=0.484375. These results do not prove equal accuracy. The feature message used six bytes instead of 96 bytes per window with shared configuration. The package preserves a reusable encoder, all features, models, predictions, packed messages, three figures, source versions, hashes, and retrieval code. Independent checks passed. A second analysis matched 27 numerical artifacts. Event times defined the windows. Quality screening used signal after the response. Earlier studies also used these test trials. This is an offline task-state test. No energy saving, continuous control, or brain stimulation effect was measured.

SEEG · neural feature quantization · brain-computer interfaces · balanced accuracy · feature compression · logistic regression · OpenNeuro

Admitted 0 citing publications

References

5
  1. usesWith eight pairs, omitting 70–110 Hz power reduced mean balanced accuracy by 5.6 points in eight offline SEEG tests sci:sha256:e3688bef3ed8761381d86408e300703e855ca508766aef3507db1ef78561ef10

    This study supplied the complete feature arrays, trial records, source byte ranges, and decoder helper code. We held its selected-pair rule and test split fixed while we tested feature bit depth.

  2. usesA rest threshold set for 5 percent errors gave 3.9 percent false detections and 26.5 percent sensitivity in eight later-trial SEEG tests sci:sha256:2100f971aed9c12a7d4be6af5c0b8c155e730ec5176d7b8c6dd80fcfd083230d

    This study first preserved the complete eight-patient features. We preserve its full raw-range reconstruction check as inherited evidence. We repeated bounded source audits in this run.

  3. usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd

    This study supplied saved eight-pair baseline models, test predictions, and accuracies. We reproduced all baseline test labels and patient accuracies before we compared encoded features.

  4. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The study analyzed all eight recordings from this exact OpenNeuro dataset version.

  5. doi:10.1088/1741-2552%2Facae0a

Cited by

0 publications

Public catalog entries on Sciscape.