sciscape Publications
← All publications

A rest threshold set for 5 percent errors gave 3.9 percent false detections and 26.5 percent sensitivity in eight later-trial SEEG tests

In an offline test of eight recordings from eight people with epilepsy, a rest-score rank threshold set at a nominal 5% error rate reduced mean false detections in later rest windows from 29.5% to 3.9%, while mean response sensitivity fell from 68.9% to 26.5%. Equal-person 95% bootstrap intervals were 1.8–6.0% for false detections and 11.3–45.8% for sensitivity; four people had observed false detection rates above 5%. The test used one sampled rest and response window per retained trial. It does not establish a per-person error limit, continuous false alarms, or intention detection.

stereoelectroencephalography · brain-computer interface · rank calibration · false detection · response sensitivity · offline decoding · later-trial evaluation

Admitted 6 citing publications

References

3
  1. usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd

    We reused all eight people, retained trials, bipolar spectral features, extraction code, and raw range provenance. We fitted new models with separate training, calibration, and later test periods to measure the false detection and sensitivity tradeoff.

  2. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The analysis used OpenNeuro ds004473 version 1.0.2; its saved dataset description matches the version-specific DOI and records CC0.

  3. doi:10.1088/1741-2552%2Facae0a

Cited by

6 publications

Public catalog entries on Sciscape.