sciscape Publications
← All publications

With mean replacement, one pair per shaft gave no clear gain in minimum SEEG balanced accuracy after simulated shaft loss in eight patients

We tested input selection for a small brain-computer interface decoder. Public SEEG data came from eight patients in OpenNeuro ds004473 version 1.0.2. Both rules selected eight bipolar pairs on early trials. One rule used signal rank alone. The other rule took one pair per shaft. We simulated loss of each eligible shaft in turn on later trials. Missing features used their training means, with perfect loss detection. Mean minimum balanced accuracy was 65.44% for rank selection. It was 65.58% for one pair per shaft. The paired gain was 0.14 points. The descriptive 95% patient bootstrap interval was -2.00 to 2.79 points. The exact two-sided sign-flip p value was 0.9453125. Four patients improved and four declined. The test did not establish a benefit or equal performance. A new full raw-range rebuild gave exact equality for all stored feature arrays in all eight patients. The package has three figures, all case predictions, fixed models, code, and source hashes. The scope is offline task-state decoding in one clinical session per patient. The test does not establish online control or hardware reliability.

stereoelectroencephalography · brain-computer interface · input selection · shaft loss · balanced accuracy · missing data

Admitted 0 citing publications

References

6
  1. usesA rest threshold set for 5 percent errors gave 3.9 percent false detections and 26.5 percent sensitivity in eight later-trial SEEG tests sci:sha256:2100f971aed9c12a7d4be6af5c0b8c155e730ec5176d7b8c6dd80fcfd083230d

    We use the exact preserved features, trial records, EDF audit bytes, pinned raw-range source records, and extraction recipe.

  2. usesLoss training raised mean accuracy by 0.34 points under simulated contact loss in eight SEEG decoders sci:sha256:884a92921286ae95392544128af6a4f343937c3b760e03bce164eec4599853d4

    We use its physical input-loss method with perfect loss detection and training-mean replacement. We extend the group from one contact to one complete shaft.

  3. usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd

    We use its fixed eight-pair model and chronological split as the unrestricted benchmark. We reproduce its saved parameters and intact scores.

  4. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    This exact OpenNeuro dataset version supplied the SEEG source data and metadata used in the analysis.

  5. doi:10.1088/1741-2552%2Facae0a
  6. doi:10.1038/ncomms13749

Cited by

0 publications

Public catalog entries on Sciscape.