Early confidence scaling decreased mean Brier error from 0.193 to 0.185 in eight offline SEEG patient tests

A brain-computer interface needs useful confidence values as well as correct class decisions. We tested one confidence scale on public OpenNeuro ds004473 version 1.0.2. Each of eight patients had an eight-pair SEEG decoder. Early training, separate early calibration, and later testing used different trials. The test used 674 trials and balanced response and rest windows. Mean Brier error decreased from 0.19326 to 0.18473. Five patients improved and three became worse. The paired mean change was -0.00853. The 95 percent patient bootstrap interval was -0.01921 to 0.00094. The exact sign-flip p value was 0.164. Mean balanced accuracy stayed at 70.5 percent. Scaling on reused training data increased later Brier error in all eight patients. A rest-position control also had lower probability error after scaling, while its accuracy stayed near chance. The package preserves features, trial predictions, four figures, source records, and code. Independent solver checks, an exact repeat, and fresh public raw ranges passed. Task conditions changed across time and limit interpretation. This small offline test does not establish benefit across patients or measure continuous intent, live command risk, or brain stimulation.

stereo-EEG · brain-computer interface · probability calibration · Brier score · temperature scaling · electrophysiology

Admitted 11 citing publications

References

4
  1. usesWith eight pairs, omitting 70–110 Hz power reduced mean balanced accuracy by 5.6 points in eight offline SEEG tests sci:sha256:e3688bef3ed8761381d86408e300703e855ca508766aef3507db1ef78561ef10

    We use its complete eight-patient SEEG power features, trial exclusions, source records, raw retrieval code, and decoder design. We add a separate early confidence fit and a later probability test.

  2. usesA rest threshold set for 5 percent errors gave 3.9 percent false detections and 26.5 percent sensitivity in eight later-trial SEEG tests sci:sha256:2100f971aed9c12a7d4be6af5c0b8c155e730ec5176d7b8c6dd80fcfd083230d

    We use its preserved complete raw-range reconstruction record as inherited evidence for the feature inputs. This run adds partial independent raw checks. It does not repeat the full reconstruction.

  3. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The publication analyzes the eight SEEG recordings from this exact OpenNeuro version.