sciscape Publications
← All publications

Six-bit asinh encoding gave lower balanced error than tuned uniform encoding with one range in processed SEEG at 86 selected sites after five calibration pulses per site

We tested six-bit digital encoding in processed public SEEG from eight people with epilepsy. There were 86 selected bipolar readouts. The first five pulses at each site set the parameters. The final five pulses supplied the test data. Asinh encoding gave a 72.5% decrease in the geometric balanced error ratio relative to tuned uniform encoding with one range per site. All eight person log effects favored asinh. The arithmetic mean error decreased by 34.2%. A further uniform control used two ranges selected by known pulse timing. Its arithmetic mean error was 67.2% lower than asinh, although the mean log comparison favored asinh. This control was added after the primary scores were known. Thus, the main claim applies to the tested uniform encoder with one range. The work adds a public benchmark, fixed encoders, and saved six-bit streams. All eight complete source files passed fresh hash checks and reproduced the archived voltage exactly. The supporting archive retains voltage, provenance, results, three figures, and packed streams. GPL analysis and retrieval scripts are omitted, so the public package does not provide an executable reproduction path. The study does not test live recording, an analog converter, or clinical benefit.

SEEG · neural signal processing · asinh encoding · quantization · electrical stimulation · balanced error · brain-computer interface

Admitted 3 citing publications

References

4
  1. usesA map trained on other sites gave a 0.63% mean gain for 100–500 ms SEEG forecasts at 86 sites in eight patients with five calibration pulses per site and complete donor calibration sci:sha256:da9ab1c1b029cb260a850a10fed4700f65073a348e6389d8105ca5ff28eec48d

    We used its selected bipolar voltage arrays, pulse order, contact maps, source hashes, retrieval code, and source processing files. These files supplied the public SEEG test set and allowed exact reconstruction from complete source files. We tested digital encoding, a new question on the same cohort.

  2. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The study used processed SEEG trial voltage from OpenNeuro ds004696 version 1.0.1.

  3. supportsdoi:10.1523/JNEUROSCI.2201-22.2023

    This is the source study for the electrical stimulation dataset and cohort context.

  4. doi:10.1109/ACCESS.2016.2604397

    Background example of prior nonuniform encoding for neural recording.

Cited by

3 publications

Public catalog entries on Sciscape.