sciscape Publications
← All publications

A calibration waveform reduced mean relative six-bit code error at 86 selected processed SEEG sites in eight people with known pulse times

We tested voltage codes on public processed SEEG from eight people. Each of 86 selected sites used five early pulses for fitting and five later pulses for testing. All codes had separate fitted ranges and known pulse times. At six bits per sample, a shared calibration waveform gave a mean site log error ratio of -1.66 dB against direct coding. The 95% person bootstrap interval was -2.79 to -0.54 dB. Seven of eight people had a decrease. The arithmetic mean of scaled after-pulse error fell by 7.0%. The waveform added 3,932 bytes per site. Four-bit waveform error exceeded six-bit direct error at 84 of 86 sites. Thus, this test did not establish a byte saving at matched error. The package preserves input windows, code, packed streams, source hashes, results, figures, and reproduction steps. The study is exploratory and uses a cohort from prior work.

stereoelectroencephalography · SEEG · signal compression · waveform predictor · electrical stimulation · quantization

Admitted 1 citing publication

References

5
  1. usesSix-bit asinh encoding gave lower balanced error than tuned uniform encoding with one range in processed SEEG at 86 selected sites after five calibration pulses per site sci:sha256:6693e6c093ab824c9299d7b51f1dfcb8ad1a30f16351ec7367de7ffadcdc0f91

    Its encoding benchmark showed that separate before and after voltage ranges change the comparison. We used separate tuned direct ranges as the baseline and tested a new shared waveform residual and constant control on the reused cohort.

  2. usesLater input gave a small, uncertain error reduction for five-pulse SEEG forecasts at 86 sites in eight people sci:sha256:9541f97fcea19f1eca7a6f8adde2650a2ec1e865855212bbed2af09ea10d877d

    We used its 16 source-checked voltage and pulse files, corrected source event mapping, fixed five-pulse readout choices, source metadata, and public retrieval recipe. All copied data hashes matched its archived manifest.

  3. usesA fixed background power rule increased 20 to 500 ms SEEG size forecast error after five calibration pulses in eight sessions sci:sha256:b8e5ae61a5b00cfa06f9294e3694b2df810dda59e3ec09aa69ad2cbe63b674c4

    The download helper adapts its public MAT retrieval code through the direct data parent. We retained the source hashes, author credit, and license notices.

  4. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis uses processed SEEG voltage data from OpenNeuro ds004696 version 1.0.1; the exact version is recorded with a CC0 license.

  5. supportsdoi:10.1523/JNEUROSCI.2201-22.2023

    This source study reports distinct, repeatable limbic responses to electrical stimulation, motivating the waveform test; it does not establish the compression result.

Cited by

1 publication

Public catalog entries on Sciscape.