An RMS bound allowed every 4–10 Hz reference phase at a 50 ms forecast cutoff in seven SEEG rest records
We tested whether an early rest voltage bound can restrict an offline phase label for timed brain interfaces. We used public SEEG rest data from seven people in OpenNeuro ds006065 version 1.0.0. One anatomical proxy bipolar pair was used per person. A centered 1,001-tap complex filter defined a nominal 4–10 Hz reference. Early rest set a 95th percentile RMS bound on unavailable voltage. We derived the exact ellipse of reference values allowed by that bound. At a cutoff 50 ms before the target, zero was strictly inside the ellipse at all 14,000 test targets. Every reference phase was therefore possible. No target gave a phase range with a half-width of 15 degrees or less. The real later voltage met the bound at 95.12% of targets. Even an oracle bound set to the actual later RMS permitted all phases at the main cutoff. At 750 ms after the target, the early bound gave 15 degree ranges at 78.31% of targets. Every observed error outside an accepted range occurred when the input bound failed. Positive cutoffs are delayed reference reports. The result applies to this finite filter and an energy set without temporal constraints. Learned rhythm models can impose extra constraints. The package has the proof, range tool, all inputs and ranges, three figures, source hashes, and reproduction steps. Fresh public retrieval matched all seven contact arrays. Repeated analysis matched all numerical outputs.
stereoelectroencephalography · SEEG · phase estimation · forecasting · finite impulse response filter · energy bound · brain-computer interface
References
4- usesReplacing input beyond 50 ms with an early mean changed 34.7% of 2 s FIR 4–10 Hz phase labels by more than 45 degrees in seven SEEG rest records sci:sha256:1e7c0af4e5a1767d2a1a9c225fa1cadf68f448ed38cfdafb1ca65b801738bc6a
Reuses its seven selected 180 second contact subsets, anatomical selection provenance, finite complex reference definition, and MIT licensed source retrieval and check code. This study fits new early RMS bounds and tests all real future voltages within each bound. Fresh public source retrieval matched the reused arrays.
- usesdoi:10.18112/openneuro.ds006065.v1.0.0
Uses the public rest SEEG signals from OpenNeuro ds006065 version 1.0.0; the package records the source commit, object versions, and byte-range hashes.
- doi:10.1038/s41467-025-59417-7
- doi:10.1016/j.neuroimage.2020.116761
Cited by
3 publicationsPublic catalog entries on Sciscape.
- usesTwo exact bounds certified a 7 Hz SEEG filter phase after simulated gaps in nine rest records under voltage caps
This prior phase-range work supplied the distinction between a numerical filter phase and biological phase, and the need to report input-bound failures. Our present causal state and past-gap box differ from its centered filter and future RMS set.
- usesThe phase range midpoint reduced the first certified wait for a 7 Hz filter after simulated gaps in nine SEEG rest records with known states and voltage limits
Supplied related exact phase-range context and the distinction between filter phase and neural phase. Its centered finite filter and future energy set differ from the causal state and past real-sample box here. No code, data, or numerical result from that work entered this benchmark.
- usesAn exact rule raised causal 6 Hz SEEG forecast acceptance by 2.23 percentage points in 21 patients under the stated 20 ms RMS error model
Its exact RMS phase ranges supplied related method context for the real input error ellipse. We read its description after the primary score calculation. No code, voltage, or numerical result entered this benchmark.