sciscape Publications
← All publications

Three DPSS tapers gave lower mean Brier error than Hann in eight reused SEEG recordings with 500-sample buffers

We tested whether three spectral tapers improved a reader of two task states. The public source was OpenNeuro ds004473 version 1.0.2. We reused selected contact pairs and exact voltage buffers from eight people. Each 500-sample buffer lasted about 0.5 seconds. Four power estimates used the same buffers, bands, trial split, and logistic model rule. Each reader learned from early trials and predicted later trials. Three DPSS tapers gave mean test Brier error 0.177218. Hann gave 0.190139. The paired change was -0.012921, with a 95% person bootstrap interval from -0.021412 to -0.004048. Seven of eight recordings had lower error. The test used 674 later trials. Each person had equal weight in the means. Gaussian controls showed lower power variation with three tapers. Other controls showed changed time weights and frequency responses. These controls do not identify the cause of the decoding gain. This exploratory study reused earlier test trials. Its labels describe event-aligned task states under offline eligibility rules. It does not establish live control or stimulation benefit. The package preserves exact inputs, code, source versions and hashes, features, models, predictions, uncertainty draws, three figures, and reproduction instructions. Independent checks passed. A full replay matched all 31 numerical outputs exactly. Fresh source checks matched trial ranges for all eight people and all retained input arrays for one recording.

SEEG · spectral estimation · DPSS · Hann taper · Brier error · brain-computer interface

Admitted 12 citing publications

References

6
  1. usesFiltering before fourfold sample removal gave 70.6% mean balanced accuracy in later trials from eight SEEG recordings sci:sha256:8bc11c5e9496aba0a89fbf8535edb5ce1336d5a00cc9df2b9795ddfb7b8ddde4

    This package supplied the exact digital buffers, fixed selection, source metadata, numerical helpers, and retrieval code. We used them for a matched spectral comparison.

  2. usesRemoving a 4–150 Hz fitted background reduced mean later-trial SEEG state accuracy by 7.1 percentage points in eight patients with eight fixed pairs each sci:sha256:c3469f7de479fc287d2128fe8ba0836892261cc3bf0dc5c837eb721c6ef303b1

    This record supplied the earlier compact buffers in the inherited input chain. The present package preserves their exact selected samples and source records.

  3. usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd

    This record fixed the original trial eligibility and early contact pair selection. Its EDF helper code supports the inherited retrieval method.

  4. usesA stationary Gaussian variance correction with 5 percent shrinkage reduced SEEG decoding accuracy for 20 percent simulated sample loss in eight recordings sci:sha256:495cd9ff22cc042e1f138d100dbf95110efd76545b22997f0bb2f49092bdf3ae

    This record supplied the earlier digital voltage extraction and pinned source range records. Those records support fresh source checks and input retrieval.

  5. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    This versioned public dataset supplied the SEEG recordings and source metadata used for the eight-person matched comparison.

  6. doi:10.1088/1741-2552%2Facae0a

Cited by

12 publications

Public catalog entries on Sciscape.