The last 250 samples gave mixed Brier error changes against 500 samples in eight SEEG task state readers with three tapers

We tested whether the last 250 samples could replace a 500-sample SEEG history in eight fixed readers of task state. The public source was OpenNeuro ds004473 version 1.0.2. Each reader used eight bipolar pairs, three bands, and three DPSS tapers. Readers learned from early trials and predicted states in 674 later trials. Mean Brier error changed from 0.177218 to 0.177332. Error rose in five people and fell in three. The mean paired change was +0.000114, with a 95 percent person bootstrap interval from -0.020202 to +0.019802. This result does not establish equivalent performance. In a fixed secondary check, the last half had lower mean error than the first half with DPSS and Hann tapers. The full and last-half windows had the same endpoint. This test does not measure lower device delay or stimulation benefit. The people and test trials were used in prior work. The package preserves exact digital inputs, source versions and range hashes, code, all readers and predictions, three figures, and reproduction instructions. Independent checks covered 112 readers and 56 complete feature arrays. A clean numerical replay matched 26 output files and 1014 arrays.

stereoelectroencephalography · SEEG · signal processing · Brier error · brain-computer interface · DPSS tapers · window length

Admitted 3 citing publications

References

5
  1. usesThree DPSS tapers gave lower mean Brier error than Hann in eight reused SEEG recordings with 500-sample buffers sci:sha256:6b6f409ccedb538d81478030fd7ac7ab8512d1e3bcef6a9af4feebff6c7e2f5e

    This study supplied the exact 500-sample digital buffers, source records, spectral helper, model helper, and retrieval code. We kept its full-window rules and tested first and last halves.

  2. usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd

    This study fixed the inherited trial eligibility and early contact pair selection. Its choices define all reader inputs in the present test. Its EDF helper also supports inherited retrieval code.

  3. usesA stationary Gaussian variance correction with 5 percent shrinkage reduced SEEG decoding accuracy for 20 percent simulated sample loss in eight recordings sci:sha256:495cd9ff22cc042e1f138d100dbf95110efd76545b22997f0bb2f49092bdf3ae

    This study supplied the original digital voltage extraction and pinned source range records in the inherited input chain. Those records enabled fresh source checks and exact input retrieval.

  4. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The study used the recorded SEEG task data from OpenNeuro ds004473 version 1.0.2; the saved dataset metadata state CC0.

  5. doi:10.1088/1741-2552%2Facae0a