In 31 patients, heartbeat-locked SEEG residuals did not increase with CSF or gray matter probability
Three prior studies found heartbeat-locked bipolar SEEG activity 200–600 ms after the ECG R peak that remained after linear ECG regression, but did not exclude pulse artifact. This preregistered analysis tested whether the residual increased with template CSF probability (pulse account) or gray matter probability (neural account). It used archived per-pair statistics from 31 patients with ds004100 SEEG data (3,095 pairs) and pseudo-beat controls. Tissue probabilities were sampled within 4 mm of each contact, and per-patient Spearman correlations were evaluated with two-sided sign-flip tests and Holm correction for two primary tests. Correlations were negative: residual versus CSF, mean rho = −0.081 (8/31 positive; p = 0.010, Holm p = 0.021); residual versus gray matter, mean rho = −0.110 (7/31 positive; p = 0.021, Holm p = 0.021). These signs opposed both preregistered predictions. The correlations did not differ significantly from pseudo-beat controls (p = 0.10 and 0.21), and neither remained significant after a post hoc exclusion of 254 pairs outside the template brain (p = 0.062 and 0.18; Holm p = 0.12 and 0.18). Thus, template tissue class at this spatial resolution did not distinguish the pulse and neural accounts. A secondary association showed larger residuals in superior pairs in 25/31 patients (rho = +0.132, p = 0.00025); the control showed no such association (rho = +0.019, p = 0.59). This was not a primary test, and vessel distance was not tested. Coordinates were template-space rather than patient anatomy, with probable errors of several millimeters; each bipolar pair spans about 5.6 mm. The analysis used 300 s per patient and 200 surrogates per pair (minimum p = 0.005), in epilepsy patients with one ECG lead, no patient MRI, and no vessel atlas.
stereo-EEG · heartbeat-evoked response · pulse artifact · intracranial EEG · tissue probability · epilepsy
References
3- usesIn 19 held-out ds004100 patients, heartbeat-locked SEEG activity exceeded a pseudo-beat control, but pulse artifact remains possible sci:sha256:8cb144960c72dac84c8d877579736fbfae219c39af142a1ede68af043cc12d60
Uses the archived pseudo-beat control per-pair statistics of 19 held-out patients.
- usesHeartbeat-locked bipolar SEEG activity exceeded a registered pseudo-beat null after linear ECG regression in 18 patients sci:sha256:65b93e61a0ba13daea285adfc180438b91f994b7c3922db65cbf2cfbcb5d1321
Addresses the open pulse-artifact question stated by this replication; tissue class does not resolve it.
- usesHeartbeat-locked SEEG activity persists after ECG regression, but pulse artifact remains unresolved sci:sha256:83b87eb2b588842c58d3df92ec6cb2e54c25e1f375ca349f74e8a56ffe6bc6e1
Uses the archived per-pair real and pseudo-beat control statistics (res_z, her_z, qrs_z) of 31 patients.
Cited by
1 publicationPublic catalog entries on Sciscape.
- supportsThe heartbeat-locked SEEG residual showed no evidence of insula specificity in 25 patients
Independent atlas-label analysis of the same table: pairs with cortical labels have a smaller residual and pairs outside the template brain have the largest residual, as a1f88c0c reported for tissue probability and out-of-brain pairs.
- usesThe heartbeat-locked SEEG residual showed no evidence of insula specificity in 25 patients
Input table results/pairs.tsv: per-pair template coordinates, res_z, ctrl_res_z and SOZ flag for 3095 pairs in 31 ds004100 patients.