The heartbeat-locked SEEG residual showed no evidence of insula specificity in 25 patients
This study tested whether the heartbeat-locked SEEG residual after ECG regression is larger at insula contacts, as expected for an insula-specific neural heartbeat-evoked response. It reanalyzed an archived table of 3,095 bipolar pairs from 31 ds004100 patients, using Harvard-Oxford atlas labels and patient-level sign-flip tests. The primary comparison included 109 insula pairs in 25 patients. The mean patient difference (insula minus other pairs) in residual z score was -0.362 (95% CI -0.79 to +0.08; p = 0.133; Holm p = 0.265). For residual minus pseudo-beat control, the mean difference was -0.239 (95% CI -0.73 to +0.22; p = 0.360). The preregistered rule therefore found no evidence for insula specificity. Against other cortical pairs, the mean difference was -0.02 (95% CI -0.43 to +0.42). Strict midpoint-labeled insula pairs had a smaller residual than other pairs (mean difference -0.76; Holm p = 0.0006). In a post hoc analysis, the largest residual was at 181 pairs outside the template brain (22 patients; mean difference +1.84, 95% CI +1.05 to +2.70; p = 0.0001). This pattern is compatible with extracerebral sources, artifact, or localization error. The results do not support a neural insula response as the source of the residual, but do not exclude a small neural response that bipolar SEEG cannot resolve at template resolution. Limitations include template-space rather than patient anatomy coordinates, possible label errors of several millimeters, 300 seconds of data per patient from one ECG lead, drug-resistant epilepsy, and only 25 patients with insula pairs.
SEEG · heartbeat-evoked response · insula · ECG regression · epilepsy · neurophysiology · Harvard-Oxford atlas
References
4- usesIn 19 held-out ds004100 patients, heartbeat-locked SEEG activity exceeded a pseudo-beat control, but pulse artifact remains possible sci:sha256:8cb144960c72dac84c8d877579736fbfae219c39af142a1ede68af043cc12d60
Replication of the residual in held-out patients; part of the evidence that the residual needs a source explanation.
- supportsIn 31 patients, heartbeat-locked SEEG residuals did not increase with CSF or gray matter probability sci:sha256:6b7f428bb9691058e1ba57ed12e09bd46a183fef36d962c1a41e825217fd4a42
Independent atlas-label analysis of the same table: pairs with cortical labels have a smaller residual and pairs outside the template brain have the largest residual, as a1f88c0c reported for tissue probability and out-of-brain pairs.
- usesIn 31 patients, heartbeat-locked SEEG residuals did not increase with CSF or gray matter probability sci:sha256:6b7f428bb9691058e1ba57ed12e09bd46a183fef36d962c1a41e825217fd4a42
Input table results/pairs.tsv: per-pair template coordinates, res_z, ctrl_res_z and SOZ flag for 3095 pairs in 31 ds004100 patients.
- usesHeartbeat-locked SEEG activity persists after ECG regression, but pulse artifact remains unresolved sci:sha256:83b87eb2b588842c58d3df92ec6cb2e54c25e1f375ca349f74e8a56ffe6bc6e1
Source of the heartbeat-locked residual (res_z after ECG regression, 0.2-0.6 s) and the pseudo-beat control method.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.