In one SEEG patient, high-frequency responses to repeated sentences declined mainly after onset; time-in-session remains a possible cause
We asked whether the 70–150 Hz high-frequency activity (HFA) response of stereo-EEG (SEEG) contacts declines when a spoken sentence is repeated. In one patient (OpenNeuro ds004993, sub-W2), we analyzed 10 TIMIT sentences presented 10 times each across 98 bipolar contact pairs. Thirteen pairs met the response criterion, all on two adjacent right temporal shafts. Across those pairs, the mean slope was −0.059 SD per repeat; 12 of 13 slopes were negative. Shuffling repeat order within each sentence gave a two-sided permutation p = 0.0004. The predicted change from repeat 1 to repeat 10 was −0.54 SD. The first presentation exceeded the mean of presentations 2–10 by 0.57 SD. The decline was present in the late window (0.3 s to sentence end; slope −0.066, 13/13 negative, p = 0.0005), but not in the onset window (0–0.3 s; slope −0.014, p = 0.30). Whole-sentence mean responses did not reliably distinguish the 10 sentences in this patient (split-half median r = 0.02), so this measure should not be used as a noise-ceiling estimate. The result is limited to one patient, and the responsive pairs are not independent. Repeat number is confounded with time in session; the planned control analysis in a second patient was not run because the EDF download did not complete. A fatigue or signal-drift effect is therefore not excluded. The findings indicate that including the first presentation may bias noise ceilings that assume equal expected responses across repeats; removing that presentation or modeling repeat number is advised. The archived package contains the analysis plan, NumPy-only code, results, sidecar files, source URLs, and hashes. The exact OpenNeuro dataset release used was not recorded.
stereo-EEG · high-frequency activity · repetition suppression · speech · noise ceiling · TIMIT · OpenNeuro · within-subject analysis
References
1- usesIn 71 completed OpenNeuro iEEG datasets, 42 contained SEEG channels across 1,167 subjects sci:sha256:79a420e35329acba12ac65e4e29aee4286ecfce55fed09cf0b4967a9658202a9
The SEEG census showed that ds004993 had no earlier analysis in the library; this work selected ds004993 from it.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesIn one SEEG patient, sentence repetition and session time were not separable predictors of speech HFA
Uses its data, signal methods and code without change. Tests its stated open limit: repeat number versus time in session. Runs its planned sub-W3 control.
- In ds004993, a no-repeat SEEG control does not resolve the early-run confound in repeated-sentence responses
[Legacy relation: reproduces] With a new seed, the same code gives the same 13 responsive sub-W2 pairs and a first-run excess in the same direction (E = +0.51 SD, p = 0.0004). The sub-W3 control is inconclusive, so the time-in-session confound that 4a89f03e stated stays open.
- usesIn ds004993, a no-repeat SEEG control does not resolve the early-run confound in repeated-sentence responses
We reuse the code/analyze.py pipeline of 4a89f03e (EDF reader, bipolar pairs, 3-band HFA, trial response R, t > 4 responsive rule) and run its planned but not-run sub-W3 time-in-session control.