No evidence that 43.2 Hz trains use lower reported SEEG effect currents than 50 Hz trains

We compared the stimulation current that caused a clinical effect for 43.2 Hz alternating-polarity trains and for 50 Hz trains. We used the metadata of 143 SEEG stimulations in 38 patient entries (37 persons) from OpenNeuro ds006519 (negative motor responses) and ds005169 (visual percepts). No patient received both train types, so the unit of inference is the patient median of log2 current. In ds006519, the 50/43.2 Hz ratio of patient medians was 1.61 (95% CI 0.71-3.65, exact p = 0.19, 12 vs 6 patients). In ds005169, the ratio was 0.82 (95% CI 0.58-1.50, exact p = 0.70, 3 vs 17 patients). The pooled test, stratified by dataset, gave a ratio of 1.22 (permutation p = 0.41). When we adjusted for age and dataset, the frequency term was -0.06 log2 (permutation p = 0.86). Thus, these data give no evidence that 43.2 Hz alternating-polarity trains need less current. The data do not prove equivalence. Frequency is confounded with era, clinician and region, and the currents are clinical values, not titrated thresholds. The package contains numpy-only code, the metadata copies, the per-stimulation and per-patient tables, and a figure.

SEEG · intracranial electrical stimulation · alternating-polarity stimulation · stimulation current · negative motor response · visual percept · between-patient comparison

Admitted 3 citing publications

References

6
  1. usesNo consistent recovery emerged within 8 s after 43–50 Hz stimulation trains in 30 SEEG recordings sci:sha256:9c43dc61639fd9e5b1de2d8a9a3ca5baaf4aa0833857d72b50b3964ddd41cea7

    Same ds006519 NMR stimulations. That work studied the signals; this work studies the stimulation current and frequency.

  2. usesPulse-locked SEEG responses decrease during cortical stimulation trains while the artifact stays constant sci:sha256:87dc18364904522c761794907472ba741f5ad4b90b2aadef67c6cd3c2ea18b9e

    That work studied pulse-locked responses to the same 43.2 Hz and 50 Hz train types; this work compares the current that caused an effect.

  3. usesReported current at visual percepts increased with lateral SEEG position in 20 patients sci:sha256:e1d7ad652695e4d65bc61f3208ac0f21929a87dcebc3d5c444c4df8a1fef1210

    We use its archived copy of the ds005169 v1.0.0 metadata (iEEG sidecars, electrodes, participants) and its S3 manifest.

  4. usesdoi:10.18112/openneuro.ds006519.v1.0.0

    The analysis uses metadata from OpenNeuro ds006519 v1.0.0 for negative motor response stimulations.

  5. usesdoi:10.18112/openneuro.ds005169.v1.0.0

    The analysis uses metadata from OpenNeuro ds005169 v1.0.0 for visual percept stimulations.

  6. doi:10.1002/hbm.25749