The gamma difference from onset to 10–30 seconds after seizure end gave mean within-shaft SOZ AUC 0.833 versus 0.747 for onset increase in 29 SEEG patients
We tested a fixed gamma difference in 64 public seizures from 32 SEEG patients in OpenNeuro ds004100 version 1.1.3. The score compared the first ten seconds of seizure onset with 10–30 seconds after seizure end. It equals onset increase plus post-seizure decrease, so the baseline cancels. No score weights were fitted. In 29 patients with mixed-label shafts, mean clinical SOZ AUC was 0.833 versus 0.747 for onset increase. The mean gain was 0.086. Its patient bootstrap 95% interval was 0.019–0.160. The primary sign-change p value was 0.023524 under an independent, symmetric patient null. The bootstrap population claim assumes independent, exchangeable patients. Fourteen patients improved, seven worsened, and eight tied. The median gain was zero. The gain interval included zero without shared contacts and with the late period. Added value over post-seizure decrease alone remained uncertain. Mean score rank agreement across two runs was 0.536 versus 0.363 for onset increase. This work reuses a known cohort and does not test surgical outcome. All 64 source records were retrieved again. All feature arrays and 320 range hashes matched the earlier package. The package preserves code, data, source pins, metadata, results, figures, checks, and reproduction instructions.
stereoelectroencephalography · seizure onset zone · gamma power · intracranial EEG · AUC · within-shaft ranking · postictal activity · repeat agreement
References
4- usesGamma decrease 10–30 seconds after seizure end gave mean within-shaft AUC 0.790 for SOZ marks in 29 ds004100 SEEG patients sci:sha256:99be67b99ddbb5d8f4a313e37c0796d3d1720b9c5256eb23bdc178856757d497
This work uses its 64 gamma feature files, fixed cohort, clinical metadata, pinned public EDF ranges, and extraction code. All records were retrieved again. The new test compares a fixed onset to post-seizure score with onset increase and post-seizure decrease. New retrieval reproduced all 640 feature arrays and 320 signal range hashes. The post-seizure comparator reproduced mean within-shaft AUC 0.790175 in the same 29 patients.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Source SEEG signals and clinical channel and event metadata from OpenNeuro ds004100 version 1.1.3.
- doi:10.3389/fneur.2026.1862336
Related background on ictal gamma increase and clinical SOZ association in the same dataset; it used a different reference method and seizure period.
- doi:10.1111/epi.14621
Background on intracranial postictal EEG activity; it does not validate the score tested here.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesA fixed gamma model gave mean within-shaft AUC 0.818 for SOZ marks in 14 SEEG patients excluded from fitting
Its fixed onset-to-post-seizure gamma score led to our post-plan descriptive fixed-sum check on the frozen primary test set. It did not change the primary comparison.
- usesOnset gamma rise and post-seizure gamma fall had mean cross-seizure rank correlation -0.033 within shaft and label groups in 29 SEEG patients
This study reuses all 64 five-period SEEG feature records, source metadata, public object versions, range hashes, and the unchanged extractor. It tests a new cross-seizure onset-to-post rank relation within shaft and clinical label groups.