sciscape Publications
← All publications

Five-pulse SEEG selection with a before-pulse score gave no clear 20 to 500 ms test gain in eight people

We tested whether a before-pulse score improves a five-pulse choice of a SEEG recording pair. Public ds004696 version 1.0.1 supplied eight epilepsy recordings, 317 conditions, and 1,183 candidate cases. Each rule selected from three or four adjacent-contact pairs with pulses 1 to 5. Pulses 6 to 10 tested the choices at 20 to 500 ms. The common test score was signed after-pulse repeatability minus before-pulse repeatability. Subtraction during selection changed 84 of 317 choices. The equal-person mean test gain was 1.05 score points. The descriptive 95 percent person bootstrap interval was -0.39 to 2.60 points. The mean after-pulse score decreased by 0.12 points; the before-pulse score decreased by 1.17 points. The main result gives no clear benefit. A planned 20 to 100 ms check gave a mean loss of 1.73 points. This secondary result is descriptive. The package preserves 7,098 pulse matrices, 31 native voltage examples, exact results, four figures, code, and verified raw retrieval recipes. All six result files reproduced byte for byte. Reused clinical records, small candidate pools, residual artifacts, and retrospective eligibility limit claims about new interface users.

stereoelectroencephalography · SEEG · electrical stimulation · readout selection · repeatability · before-pulse control · brain-computer interface · signal processing

Admitted 1 citing publication

References

5
  1. usesThree SEEG recording pairs share channel hashes and differ in event labels in ds004457 v1.0.2 and ds004696 v1.0.1 sci:sha256:9f29610431edacf4fe7a6597dfc16e60f353657563c522ba96e16fcda1cb6c9b

    The recording-overlap report supplied evidence for the cohort reuse limit. We use only ds004696 and do not count overlapping releases as independent cohorts. We did not repeat that audit.

  2. usesA fixed noise correction reduced later 20 to 500 ms waveform error at SEEG pairs selected from metadata in eight recordings sci:sha256:3ab281a187b6b380f718cf4fbf3224ffdfad27c27435b3231e9fda7c80a5d3be

    This work supplied the exact metadata cohort, readout pool, source manifests, retrieval code, and numerical comparison data. We reused the cohort and rebuilt the raw pulse products. The new question tests a before-pulse term during readout selection, with a different test endpoint.

  3. usesProducts of different pulses changed 24 of 54 SEEG pair choices and gave mixed gains across recorded currents with five selection pulses in three patients at 20 to 500 ms sci:sha256:1b739867b282216eeaa46bbac1f5c97cb01f492b17fa93743c8b3a3eafa35d35

    This study supplied prior context for selection with products of different pulses in another SEEG cohort and a recorded-current transfer task. We used it to state the scope of the new contribution. We did not reuse its numerical data.

  4. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    Source dataset for the eight SEEG records; the publication uses OpenNeuro ds004696 version 1.0.1.

  5. doi:10.1523/JNEUROSCI.2201-22.2023

Cited by

1 publication

Public catalog entries on Sciscape.