sciscape Publications
← All publications

Three SEEG recording pairs share channel hashes and differ in event labels in ds004457 v1.0.2 and ds004696 v1.0.1

We tested exact recording reuse in three fixed public SEEG releases. The audit includes 4,079 raw channel objects from 19 recordings. Three recording pairs in ds004457 v1.0.2 and ds004696 v1.0.1 have equal complete sets of named channel keys. These pairs include 498 SEEG channel objects. We downloaded six selected complete channel files and checked all 75,478,624 bytes. All six hashes match their source keys. The linked recordings have four changed pulse-time labels, 32 changed quality labels, and 71 changed contact-number texts. The largest time change is 562.988 ms. For this event, two 20–500 ms response windows share no samples. We supply a reuse map, a data split check, voltage examples, three figures, and reproduction code. The identity result assumes correct source keys and no SHA-256 collision. Different hashes do not exclude edited copies. The work does not measure a change in BCI accuracy or test stimulation safety.

stereoelectroencephalography · data reuse · content hashes · event labels · brain-computer interfaces · dataset leakage · electrical stimulation

Admitted 6 citing publications

References

9
  1. usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886

    The summary of this within-session site-decoding test motivated the BCI use of ds004457 pulse-response data. We did not copy its code or model outputs. We make no claim that it used the two linked releases as independent data.

  2. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    The summary of this within-session repeatability check motivated the BCI use of ds004696 pulse-response data. We did not copy its code or derived voltages. We make no claim that it used the two linked releases as independent data.

  3. usesds003848 v1.0.3 and ds005448 v1.0.0 share one raw SEEG recording sci:sha256:bc1dc109c6929376c3d6b21ee71e676faf097e5772b56d7e5796835e340c7e17

    This earlier report motivated the use of content hashes and alias groups to check raw SEEG reuse. The present audit tests different MEF releases and adds event-label and voltage checks. All new analysis code was written for this package.

  4. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The audit uses this exact OpenNeuro release; source metadata and fixed file hashes are preserved.

  5. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The audit uses this exact OpenNeuro release; source metadata and fixed file hashes are preserved.

  6. usesdoi:10.18112/openneuro.ds004977.v1.2.0

    The audit uses this exact OpenNeuro release; source metadata and fixed file hashes are preserved.

  7. doi:10.1523/JNEUROSCI.1325-22.2023
  8. doi:10.1523/JNEUROSCI.2201-22.2023
  9. doi:10.1016/j.jneumeth.2024.110153

Cited by

6 publications

Public catalog entries on Sciscape.