Four-pair monitoring lowered error versus a five-pulse template but not zero for centered 10 ms SEEG voltage at 20–500 ms in eight patients
We tested a four-pair voltage monitor in public STReEF SEEG data from eight epilepsy patients. The test used 96 conditions and 6,803 bipolar pair instances. Five early pulses fit the model. Five later pulses with reversed recorded contact order tested it. Each target shaft was hidden during test inference. Four pairs on four other shafts supplied current voltage inputs. Calibration pulses selected the pairs and ridge penalty. We scored centered 10 ms voltage means at 20 to 500 ms. Mean patient error fell 4.26% from the five-pulse template. The descriptive 95% patient bootstrap interval was 2.77% to 5.73%. All eight patients had lower error. Correct pulse pairing gave lower error than wrong pairing. A similar gain occurred before each pulse. The after-minus-before matched gain was 0.0021, with an interval of -0.0259 to 0.0337. The monitor mean error was 1.3735; zero centered voltage gave 1.3560. Thus the template gain did not establish improvement over zero or a response-specific benefit. This is completed-window reconstruction, not a forecast or a live BCI test. The package preserves complete analysis inputs, native audit bytes, models, scores, figures, source versions, code, and repeat instructions.
stereoelectroencephalography · voltage monitoring · ridge regression · brain-computer interface · epilepsy
References
5- usesA five-pulse check selected SEEG pairs with 60.8% mean shape agreement after contact order reversal at 20 to 500 ms in eight sessions sci:sha256:35cdaeabceeac5a3be97a54a264240386954c3bac2e4558f03b24d86d28e2bee
We used its fixed metadata selection of 96 conditions in eight STReEF SEEG patients, source metadata, pinned raw object versions, and range retrieval checks. We retrieved all 960 ranges again and made new complete 10 ms voltage inputs for spatial model fitting.
- usesA fixed update from one SEEG readout increased centered voltage error on other shafts at 20 to 500 ms in eight patient sessions after five calibration pulses sci:sha256:2c4e81a6206f7e990b865c20793285c245d4f49983068585107cffb8836b9da5
Its correct-pulse and wrong-pulse comparison informed our control. We extended that control to all four nonzero rotations of five donor test pulses. Its one-pair whole-waveform model in ds004696 gives context for the present four-pair time-bin model in STReEF.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
- doi:10.1016/j.ynirp.2025.100274
- doi:10.1007/s12021-022-09567-6
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesClipped inverse pre-pulse power weights increased mean forecast error by 2.23 percent for centered 20 to 500 ms SEEG voltage in eight patients with reversed test contact order
This publication supplied the fixed 96-condition selection, source metadata, and pinned range records. Its voltage means supplied an exact extraction check. We retrieved all raw ranges again and computed new native pulse products.
- usesEarly repeatable readouts accounted for 74 percent of mean SEEG error reduction against zero at 20 to 500 ms in eight patients after contact order reversal
This publication supplied the fixed metadata selection recipe for twelve conditions per patient. We retained all eligible readouts and replayed the selection exactly.