Five-pulse consistency selection showed no clear later SEEG forecast gain over energy selection at 20 to 500 ms in seven offline sessions
Five early good pulses selected a stimulation site by response consistency or mean response energy in public SEEG data. Five final pulses tested relative waveform forecasts at 20 to 500 ms. Seven offline sessions gave 21 candidate groups and 217 target choices. Consistency selection changed 64 choices. Its mean skill gain was -0.32 percentage points, with a descriptive 95% person bootstrap interval of -10.09 to +9.24 points. The geometric later mean-waveform power ratio was 0.807 relative to energy selection. A fixed half-energy constraint gave an uncertain gain of +1.32 points and a power ratio of 0.984. The study proves the exact link between the consistency score and relative leave-one-out error and tests the response-size tradeoff. Candidate timing, retrospective labels, and reuse of the source cohort limit the result to an exploratory offline comparison. The result does not establish equal performance or live brain control. The retained files preserve exact pulse products, provenance, all scores, three figures, recorded checks, and a public retrieval description. GPL analysis and extraction scripts are excluded, so executable reproduction is unavailable from this package.
stereoelectroencephalography · electrical stimulation · waveform forecasting · response consistency · forecast skill · brain-computer interface
References
4- usesCorrection with five pulses changed 40 of 217 site choices without a clear later gain at 20–500 ms in seven offline SEEG sessions sci:sha256:a8ed92c0b82fa2b3bc3de77ad0727223791f76401eeb5eb7b9643c5a294580b8
This study uses the exact compact pulse products, common recording panels, pinned source records, and extraction code. It adds consistency selection, squared forecast skill, and response-power tradeoff checks.
- usesFive-pulse shape selection showed no clear later SEEG agreement gain over power selection in seven offline sessions at 20–500 ms sci:sha256:fd6ce0a9a7e2b0a2960bf854e978b1eb2b9fe91b878cda4ad12a05e52f7c044e
The earlier pulse-pair shape test informed the new question. This study uses a distinct consistency score that includes size variation and tests relative squared forecast error. The source cohort is reused.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The study uses the public SEEG source data and compact waveform products derived from OpenNeuro ds004696 version 1.0.1.
- doi:10.1523/JNEUROSCI.2201-22.2023
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesIndividual pulse selection gave more later SEEG shape matches than selection by pulse means in eight sessions at r ≥ 0.8
Uses this related result to define the study scope. That work selected stimulation sites for fixed targets and tested mean-waveform forecasts against power selection. This work fixes the stimulation site and compares recording-pair selection for later individual pulse shape agreement.