sciscape Publications
← All publications

Five-pulse shape selection showed no clear later SEEG agreement gain over power selection in seven offline sessions at 20–500 ms

In seven clinical SEEG sessions, selecting stimulation sites by early waveform shape did not show a clear gain in later template agreement over selection by early waveform power. The first five good pulses set each rule, and the final five tested it in a 20–500 ms response window. Mean later agreement was 0.4609 for shape selection and 0.4875 for power selection; the paired difference was −0.0266 correlation units (descriptive 95% person bootstrap interval, −0.0778 to +0.0148; exact sign-flip reference p = 0.4219). Three sessions had a positive difference and four had a negative difference. The interval permits both a loss and a small gain and does not establish equal performance. The result applies to this offline comparison and source cohort; overlapping site timing prevents interpretation as a prospective controller test. The study does not test perception, behavior, clinical benefit, neural origin, or safe stimulation settings.

SEEG · electrical stimulation · site selection · waveform agreement · brain-computer interface · pulse response

Admitted 1 citing publication

References

4
  1. usesCorrection with five pulses changed 40 of 217 site choices without a clear later gain at 20–500 ms in seven offline SEEG sessions sci:sha256:a8ed92c0b82fa2b3bc3de77ad0727223791f76401eeb5eb7b9643c5a294580b8

    This study uses all 25 compact pulse-product inputs, the shared target panel rule, source metadata, and extraction code from this publication. It adds a shape selector and an early-template to later-pulse endpoint.

  2. usesEight SEEG sessions gave an uncertain 0.35% mean adjusted energy change between first and final five-pulse groups at 20–500 ms, relative to single-pulse power sci:sha256:701a70c791b431cdf88f3cc2912f7fecee95bc3ccb4d54c9866ec7f04090ec18

    This study uses the upstream native pulse products and chronological source event mapping through its cited child publication. The package keeps the inherited source records and recipe.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analyzed compact pulse products are derived from OpenNeuro ds004696 version 1.0.1; the archived source records include the pinned source commit and full-file hashes.

  4. supportsdoi:10.1523/JNEUROSCI.2201-22.2023

    This is the source study for the clinical SEEG cohort and its single-pulse stimulation acquisition.

Cited by

1 publication

Public catalog entries on Sciscape.