sciscape Publications
← All publications

Eight SEEG sessions gave an uncertain 0.35% mean adjusted energy change between first and final five-pulse groups at 20–500 ms, relative to single-pulse power

We tested whether recorded SEEG energy changed between the first five and final five source good pulses at each stimulation site. The public source was OpenNeuro ds004696, version 1.0.1. The test used eight epilepsy sessions, 86 sites, and 886 bipolar recording edges on shafts outside the stimulated shafts. The primary 20–500 ms measure uses products between separate pulses. We subtract the pre-pulse change and divide by pooled single-pulse post-pulse power. We average edges within sites, sites within patients, and patients with equal weight. The mean adjusted change was 0.35% of pooled single-pulse power. The descriptive 95% patient bootstrap interval was −2.95% to 3.82%. The two-sided sign-flip reference gave p = 0.8516. Four patient estimates were positive and four were negative. These data did not show a clear common increase or decrease. They do not prove stable individual responses. The energy interpretation requires a constant mean within each group and zero expected error products between different pulses. Repeatable artifacts can remain. Pulse time gaps vary and there is no randomized sham. The package preserves the fixed local plan, exact compact inputs, source hashes, analysis and independent check code, all results, three figures, and retrieval instructions. Fresh retrieval of all eight public source derivatives reproduced every input array exactly. A separate replay reproduced all six numerical output files byte for byte. This is an exploratory analysis of a reused cohort, not an independent cohort replication.

stereoelectroencephalography · electrical stimulation · brain-computer interface · response energy · pulse repetition · patient bootstrap · OpenNeuro

Admitted 11 citing publications

References

5
  1. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    The inherited source extraction code originated in this publication. Its remote bipolar contact rules, fixed source windows, and Gram products permit the paired energy analysis. We do not reuse its response-based edge selection.

  2. usesThe nearest half of bipolar SEEG pairs outside the stimulated shaft had a higher mean rate of repeatable responses than the random expectation in eight epilepsy sessions sci:sha256:1a26d36b188a95ead0d43f052fc29b919849315f46a2562310a4fc08e2efdae2

    The inherited extractor uses its corrected pulse chronology and source trial mapping. These corrections permit selection of the first and final five good pulses in source event time order.

  3. usesFive early SEEG pulses gave an uncertain 4.54-point mean gain over distance for later shape agreement in eight sessions at equal pair counts sci:sha256:94bcffea84f65758436acb25fa243d454524ea877bd1de4e7db520a4fda2feb6

    We used its exact compact pulse products for all 886 edges, source metadata, input hashes, and corrected trial maps. The new analysis tests energy change rather than waveform shape. We checked these inputs against fresh downloads of all eight source derivatives.

  4. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    Source data: OpenNeuro ds004696 version 1.0.1.

  5. usesdoi:10.1523/JNEUROSCI.2201-22.2023

    Reports the clinical stimulation study that produced the source SEEG data.

Cited by

11 publications

Public catalog entries on Sciscape.