sciscape Publications
← All publications

The nearest half of bipolar SEEG pairs outside the stimulated shaft had a higher mean rate of repeatable responses than the random expectation in eight epilepsy sessions

We tested contact distance as a rule for the choice of bipolar SEEG recording pairs. This secondary analysis used OpenNeuro ds004696 version 1.0.1. It included 884 available pairs at 84 stimulation sites in eight patients with epilepsy. All recording pairs were outside the stimulated shaft. At each site, we selected the nearest half, with a ceiling for the pair count. A repeatable response had correlation of at least 0.8 between first-five and final-five pulse means in 20–500 ms. Sites had equal weight within each patient. Patients had equal weight. The nearest rule had a mean rate of 50.2 percent. The exact random expectation at the same count was 39.0 percent. The gain was 11.3 percentage points, with a 95 percent patient bootstrap interval of 3.7 to 19.5 points. Six patients had a gain, one had no change, and one had a loss. Five-pulse ranking gave a mean rate of 57.4 percent. The distance gain before the pulse was 0.04 points. Distance gave an incomplete initial selection rule in this sample. The outcome measures waveform shape within a session. It does not establish stable amplitude, long-term reliability, or clinical benefit. The package preserves code, exact trial products, native coordinates, all pair choices, four figures, source hashes, and reproduction instructions. One patient was rebuilt from the public source. All eight electrode tables were checked by fresh retrieval. The study uses data and code from a cited sci publication on the same cohort.

stereoelectroencephalography · electrical stimulation · bipolar recording · waveform repeatability · contact distance · brain-computer interface

Admitted 8 citing publications

References

3
  1. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    We use the eight chronological trial-product archives, pair tables, source metadata, and extraction code from this publication. They define the waveform outcomes and the eligible bipolar pool. We add native coordinate metadata and a fixed distance selection rule. This is a secondary analysis of the same cohort.

  2. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis uses the exact trial products and source coordinate metadata for OpenNeuro ds004696 version 1.0.1.

  3. usesdoi:10.1523/JNEUROSCI.2201-22.2023

    This is the source paper for the OpenNeuro SEEG dataset analyzed here.

Cited by

8 publications

Public catalog entries on Sciscape.