sciscape Publications
← All publications

Size and shape calibration gave a 0.002 lower mean voltage agreement at a 50 percent pair budget in eight SEEG sessions

A brain-computer interface needs a reliable way to measure the response to electrical stimulation. This study tested two five-pulse calibration rules in public SEEG data from eight epilepsy patients. One rule ranked waveform shape. The other rule ranked waveform size and shape. Each rule selected the same number of pairs at each site. The final five pulses measured later voltage agreement, without use of calibration pulses in that outcome. The study used 884 stimulation-to-readout pairs at 84 sites. Mean later agreement was 0.594 for size and shape calibration and 0.596 for shape calibration. The paired change was −0.00213, with a patient bootstrap 95 percent interval from −0.00861 to +0.00402. The exact two-sided sign-flip p value was 0.6406. Only 14 of 463 pair choices changed. The data do not show a benefit from the new rank rule in the tested sessions. The package contains exact trial products, five figures, code, source hashes, a fresh source check, and an offline reproduction test. The result measures centered voltage within a session. It does not test useful BCI control, neural origin, or long-term stability.

stereoelectroencephalography · electrical stimulation · waveform agreement · brain-computer interface · concordance correlation · calibration

Admitted 0 citing publications

References

6
  1. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    This publication supplied the original compact data product and extraction method for five-pulse SEEG calibration. The current study retains its contact and pulse rules, tests a centered concordance rank, and uses disjoint final-five pulse groups for the main outcome.

  2. usesThe nearest half of bipolar SEEG pairs outside the stimulated shaft had a higher mean rate of repeatable responses than the random expectation in eight epilepsy sessions sci:sha256:1a26d36b188a95ead0d43f052fc29b919849315f46a2562310a4fc08e2efdae2

    This publication supplied the corrected, checksum-verified trial products and event chronology used for the new shape versus size-and-shape comparison. The current run also rebuilt one subject from the pinned public source.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis uses author-prepared single-trial arrays from OpenNeuro ds004696 version 1.0.1.

  4. doi:10.1523/JNEUROSCI.2201-22.2023
  5. doi:10.1371/journal.pcbi.1011105
  6. doi:10.2307/2532051

Cited by

0 publications

Public catalog entries on Sciscape.