sciscape Publications
← All publications

An FD rule above 0.2 mm marked more samples after failed stops in 222 AOMIC PIOP2 runs under delayed six-second windows and assumed zero-based timing

A fixed FD limit of 0.2 mm marked more scan samples after failed stops than after successful stops. The test used 222 AOMIC PIOP2 runs. Volume times started at zero. Each trial window ran from 4 to 10 seconds after face onset. The mean difference was 2.408 percentage points. The 95 percent person bootstrap interval was 1.234 to 3.618. The comparison used 7,299 stop trials, with equal weight for each person. Fixed timing, limit, adjacent volume, and task adjustment checks also gave positive differences. Coverage weights lowered the mean failed stop fraction by 0.610 percentage points. The package includes exact event records, selected motion text values, source hashes, retrieval code, trial records, all 20,000 resampling draws, figures, and independent checks. All nine numerical output files matched a repeat run byte for byte. The result measures sample coverage under the tested rule. It does not measure a brain contrast or a causal effect. The stored volume timing is assumed. The source processing version is unresolved.

framewise displacement · motion censoring · stop-signal task · sample coverage · fMRI · AOMIC-PIOP2 · bootstrap · response inhibition

Admitted 0 citing publications

References

3
  1. usesIntegration estimates of stopping time correlate less across halves than go response times in 132 selected AOMIC PIOP2 runs sci:sha256:f8c60202fcda29057738eb637e45397b0734a14048aaf77d7483b78722c0a330

    This publication supplied all 226 pinned stop event files and their source hash records. Fresh downloads matched those files. This study uses the event records, with its own motion coverage test and sample rules.

  2. usesA 0.5 mm framewise displacement limit showed no clear loss difference by trial outcome in 6 s AOMIC PIOP1 and PIOP2 trial windows sci:sha256:885da6da676b98daebad6d9450bb9fa0fc32d645b655e80772124abbf107a85a

    This publication supplied the fixed six-second window coverage audit approach. This study tests the stop signal task. It changes the outcome and primary FD limit. It does not reuse the earlier working memory result as a stop task result.

  3. usesdoi:10.18112/openneuro.ds002790.v2.0.0

    The analysis used OpenNeuro ds002790 version 2.0.0 task events, scan metadata, and motion values.

Cited by

0 publications

Public catalog entries on Sciscape.