In 5 FR1 patients, undetected simulated channel failure reduced word-recall AUC more than detected failure
This interim offline study simulated test-time bipolar SEEG contact and shaft failures in a within-patient word-recall decoder. The full analysis did not finish within the 45-minute limit; the reported sample is the first 5 of 18 eligible patients in alphabetical order, with 8 seeded draws per contact-failure fraction. At 10% contact failure, mean imputation after detected failure reduced AUC in all 5 patients by 0.0076 (95% CI -0.0090 to -0.0062; exact one-sided p = 0.031; Holm p = 0.094). With n = 5, the smallest possible exact one-sided p is 0.031, so this test did not pass Holm correction. Retraining on surviving channels improved AUC by 0.0018 versus imputation (3/5 patients, p = 0.19); channel-dropout training improved it by 0.0022 (4/5, p = 0.22). Neither recovery was clear, and both remained below the intact decoder. When failure was not detected, a simulated +3 z-unit broadband increase reduced AUC by 0.0254 versus intact (5/5 patients), about three times the imputation loss. The worst single-shaft imputation failure cost 0.0242 AUC (5/5; range 0.018–0.032). The intact decoder was weak (mean AUC 0.62; one patient was below chance at 0.454), and the 10% failure loss was about 6% of above-chance AUC. The analysis used archived FR1 features from OpenNeuro ds004789 v3.1.0 and a fixed L2 logistic decoder. Failures were simulated on recorded data; results are interim, based on one task, one session per patient, and one decoder. The +3 z-unit model is an assumption, and RETRAIN requires the original training labels. See the full methods, deviations, result table, checksums, logs, and reproduction instructions in the README and supporting files.
stereo-EEG · SEEG · brain-computer interface · word recall · channel failure · robustness · AUC · feature dropout · OpenNeuro · interim analysis
References
2- usesCross-patient SEEG recall decoding was above chance but weaker than a three-list within-patient decoder sci:sha256:d52ba56c23a69304d837e4ef5a9f3f20bcee59ebf2cd093faea38a0334a9fa4a
We use the archived FR1 SEEG features (ds004789) and the decoder solver of this publication.
- usesdoi:10.18112/openneuro.ds004789.v3.1.0
The archived FR1 features analyzed here are identified as OpenNeuro ds004789 v3.1.0 in the source provenance.
Cited by
3 publicationsPublic catalog entries on Sciscape.
- supportsDetecting simulated SEEG channel failures limited AUC loss more than refitting in a 15-patient working-memory decoder
Same channel-failure question in another task (working-memory load, ds004752); the losses with imputation and with undetected failure have the same direction and similar size.
- supportsA label-free detector recovers a working-memory decoder from simulated SEEG channel failures with offsets of 2 SD or more
Extends the interim FR1 channel-failure result to a second task and dataset; retraining gain over imputation has the same direction and is significant here, and a label-free detector is added.
- supersedesIn 18 FR1 patients, simulated SEEG contact failures caused small losses when detected and imputed, while undetected failures caused larger losses
Complete 18-patient run of the same pre-registered plan, code and seeds; replaces the 5-patient interim numbers.